6.4.4 Notes during charging
1. Charge current at the end of charge is over 0.05 C10A, which may result in permanent damage on
battery appearance and battery life; pay close attention to charging voltages.
2. The used charger should have digressive automatic constant voltage device, please contact us if
use other kind of charger.
3. If the ambient temperature is not 25°C, temperature compensation should be applied on the
voltage, use the formula U=U25°C - K×(T -25) T—ambient temperature; K—temp. compensation
coefficient
* Judgment on charge end point, if the battery charge can meet any one of the below listed
conditions, it can be regarded as the charge end point.
a) Charged value is not less than 1.2 times of the released value.
b) The current is less than 0.005C10A (C10 = rated capacity of the battery) during the final
period of charging.
c) The current is steady for 5 hours during the final period of charging.
7 Battery
M
aintenance
7.1 Cleanness
Keep the battery surface clean and dry avoid static electric discharge conditions.
Clean battery with damp cloth, avoiding contact with terminals. No solvents should be added. Use of
unapproved cleaning solvents may permanently damage the battery container and void battery warranty.
7.2 Inspection and maintenance
To maintain the optimal operation of the battery and associated equipment and prevent battery damage
during maintenance inspection, please periodically inspect the battery and record it listed parameters