TROUBLESHOOTING 

Problem 

Possible Cause 

Solutions 

 

Nothing is 

displayed on LCD 

panel. 

The UPS is not on. 

Press the power switch 
again to turn on the UPS. 

Battery voltage is too low. 

Charge the battery at least 6 
hours. 

Battery fault. 

Replace the battery. 

The UPS always 
on battery mode. 

Power cord loose. 

Re-plug the power cord. 

 

 

 

Backup time too 

short. 

 

Battery voltage is too low. 

Charge the battery at least 6 
hours. 

 

Overload. 

Remove some unnecessary 
loads. Before reconnecting 
equipment, please verify 
that the load matches the 
UPS capability specified in 
the specs. 

Battery defect. 

Replace the battery. 

If any abnormal situations occur that are not listed above, please call for service 
immediately. 

 

 

 

 

 

 

 

 

Summary of Contents for PS-PGU1500VA#2B9A

Page 1: ......

Page 2: ... unit Connect Communication Cable To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the USB port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC Turn On Off the UPS Turn on the UPS unit by pressing the power switch Then the ...

Page 3: ...cted area that is free of excessive dust and has adequate air flow Place the UPS away from other units at least 20 cm to avoid interference For best performance keep the indoor temperature between 0 C and 40 C Storage All connected equipment should be turned off then disconnect from the UPS to avoid battery drain Unplug the UPS from the wall outlet Then turn off the UPS for storage Store the UPS u...

Page 4: ...PRODUCT OVERVIEW FRONT PANEL 1 LCD display 2 RGB lights 3 Power switch 4 5V USB port REAR PANEL ...

Page 5: ...1 Output socket 2 USB port 3 Circuit breaker 4 AC input ...

Page 6: ... Input voltage 3 Load level 4 Battery capacity Overload in AC mode When overload occurs alarm will beep every 0 5 second Battery Mode Alarm will beep every 10 seconds and LCD information will be displayed in the following order when LCD is touched 1 Output voltage 2 Input voltage 3 Load level 4 Battery capacity Overload in Battery mode When overload occurs alarm will beep every 0 5 second ...

Page 7: ...and disconnect the power cord from the AC power supply to properly disable the UPS 7 Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit 8 This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in location...

Page 8: ...ous through electric shock Also with dis connection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary 17 To reduce the risk of overheating the UPS do not cover the UPS cooling ven...

Page 9: ... 60Hz 1 Output Voltage range V 220V 10 Transfer time Typical 4 6ms Waveform Simulated Sine Wave Battery Type 12V9AH 2 Typical recharge time 8 hours recover to 90 capacity Dimension mm 330 115 265 Weight Kg 20kg Humidity 0 90 RH 0 40 non condensing Noise Level Less than 50dB USB Communication Port YES 5V USB 2pcs RGB light 2pcs ...

Page 10: ...battery The UPS always on battery mode Power cord loose Re plug the power cord Backup time too short Battery voltage is too low Charge the battery at least 6 hours Overload Remove some unnecessary loads Before reconnecting equipment please verify that the load matches the UPS capability specified in the specs Battery defect Replace the battery If any abnormal situations occur that are not listed a...