9
Safety measurements
The unit is equipped with safety mea-
surements that prevent basic operating
errors.
Overflow protection
When properly filled with the correct
amount of water and ingredients an
overflow during cooking cycles is very
unlikely. However, should it happen
then an impending overflow via a sen-
sor is detected and heating is stopped
immediately.
Closed system
The power does not turn on when the
top has been screwed into the original
Vegimat-pot.
The contacts in the handle of the jug
and the handle of the upper part close
the circuit in the device.
In this way, operation outside of the
protective beverage container is pre-
vented effectively.
Thermal protection and internal device
fuse
After the normal execution of a pro-
gram, a temperature of about 60°C is
not exceeded at the electronic compo-
nents after the device shell was lifted
out of the hot liquid.
The resulting hot steam is being
discharged through the inner steam
valve via a stainless steel steam pipe
upwards and exits through the outer
steam valve. In this way, the heat in
the interior of the electronics is regula-
ted.
If the current exceeds the allowable
value, the internal device fuse fires and
the power turns off permanently. In
this case, please contact our service
center.