CF(M)-3K/2K-12 SUPERCOMBI USER’S GUIDE
23
Fig 15. Turn On/Off the Panel Manually
5.7 Emergency Mode
After setting up the control parameter for the first time, if the rocker switch on
the panel cannot turn on/off the machine. Users can turn on/off the machine by
the manual switch. The control parameter will stay the same as the last
settings.
Although the SuperCombi can work properly under Emergency Mode, we
strongly recommend the customer to contact the supplier to repair the control
panel or cable as soon as possible.
6. Special Functions
6.1 Charge Pro Function
The SuperCombi can simultaneously charge the battery and provide DC
power to the DC load. The DC load has the priority to get the power. The
current charged to the battery will be dynamically controlled to make sure the
total output is less than the Max Charge Current automatically. This function
can extend the use of high AC-DC inverting capability of SuperCombi.
Figure 17 as an example, the Max Charge Current of the SuperCombi is 100A,
and if the DC load is 80A, then the charge current to the battery is 20A.