CF(M)-3K/2K-12 SUPERCOMBI USER’S GUIDE
21
status to reduce the loss. After 5 minutes, the SuperCombi will enter into Sleep
status to further reduce the loss.
Fig 14. Energy Save Mode
5.3 AC Charge
When connected to the Grid, the SuperCombi will work as a charger unless the
Rocker Switch is in the center off position. The grid will provide AC power to
the AC output1/2 and also charge the battery. The indicator on the remote
panel will turn blue (see Appendices).
If the customer presses the On/Offbutton for 3 seconds when charging,, the
SuperCombi will stop charging. The SuperCombi will continue to provide AC
power to AC Output1/2. The status indicator will turn flashing blue (see
Appendices).
If the customer presses on/off button for 3 seconds again, the SuperCombi will
enter into charge mode.
If the Charge Pro function added, more features can be expected. For details
about Charge Pro function, to see 6.2.
Note: When charging, there is no difference between Power ON and
Energy Save.
5.4 PV Charge
The solar panel will charge the battery automatically unless the SuperCombi is