DEFAULT CONFIGURATION IN TRACKSO IOT GATEWAY
Inverter ID: 1, 2, 3, 4 ….(Set as perData Logger)
Baud Rate: 9600 (Default) (Values: 9600, 19200, 38400)
Data Bits: 8 , Stop Bit: 1 , Parity: None
CONFIGURATION AT THE INVERTER END
Following is the Inverter interface which we will be accessing to completed inverter settings
SETTING THE BAUD RATE
The communication baud rate is to be set at 9600 bit/s
Menu >> Setup >> Comm Param > Baud Rate
SETTING THE INVERTER ID
The inverter ID is used to identify the inverter in a RS232 connection
Set a different inverter ID as per datalogger in the inverter. Otherwise, the inverter cannot be correctly identified.
Menu >> Setup >> Comm Param > Address
Valid for 10kW-SGTU-103, 12.5kW-SGTU-
1253, 15kW-SGTU-153, 17kW-SGTU-173,
20kW-SGTU-203, SGTU-333N
With Modbus-RTU-RS232 Output