TRACKSO WORKING 

 

1.

 

Insure correct connections as detailed in the installation guide. 

2.

 

Insert the SIM card.  

 

 

 

3.

 

Switch on the power to the TrackSo device.  (Minimum 12V/1A input is required) 

4.

 

Power LED (Red) of TrackSo IoT gateway glows and stays ON.  

 
NOTE: 

TrackSo IoT Gateway will only be able to send data if the GPRS network is available at the installed location. 

LED 

NAME 

DESCRIPTION 

GREEN 

POWER 

Light when Power on the device 

RED 

GSM 

LED Status 

Connection State 

Flashing (ON for 100ms and OFF for 100ms) 

SIM Card not found 

Flashing (ON for 500ms and OFF for 500ms) 

Searching for GSM Network 

Flashing (ON for 0.1s and OFF for 2.9s)  

Once at every 3sec 

GSM Network Registered 

Flashing twice at every 3sec 

GPRS IP Connected 

Flashing 5times 

GPRS IP Sending data 

LED OFF 

 GSM Fault 

 

GREEN 

COM TX 

Blink on data transmission in RS485 port 

YELLOW 

COM RX 

Blink on data reception in RS485 port 

 

 

 

 

 

 

Summary of Contents for 10kW-SGTU-103

Page 1: ...kW SGTU 103 12 5kW SGTU 1253 15kW SGTU 153 17kW SGTU 173 20kW SGTU 203 SGTU 333N a Type A with RS485 Output b Type B with RS232 Output 2 POM SGTU 30kW POM SGTU 50kW POM SGTU 60kW RS485 For a Modbus RT...

Page 2: ...GURATION AT THE INVERTER END SETTING THE BAUD RATE The communication baud rate is to be set at 9600 bit s SETTING THE INVERTER ID The inverter ID is used to identify the inverter in a RS485 connection...

Page 3: ...ease make the connections from the connector RS232 of PowerOne Inv RS232 Output to TrackSo IoT Gateway as mentioned in the Table KT2 4 Please provide 12V external supply to TrackSo IoT Gateway via 12V...

Page 4: ...ter settings SETTING THE BAUD RATE The communication baud rate is to be set at 9600 bit s Menu Setup Comm Param Baud Rate SETTING THE INVERTER ID The inverter ID is used to identify the inverter in a...

Page 5: ...monitoring system date and time have to be correct Menu Setup System Param Time Set The above details are mentioned in the Installation Operation Manual for PowerOne Inverters Valid for 10kW SGTU 103...

Page 6: ...the RS485 terminal as shown in A part of Figure K1 Please make the connections from the Terminal Block to TrackSo IoT Gateway as mentioned in Table P2T1 Table PT2 PowerOne RS485 connections with Track...

Page 7: ...9200 38400 Data Bits 8 Stop Bit 1 Parity None CONFIGURATION AT THE INVERTER END Press Enter on LCD panel and get into settings menu After entering into the setup interface the system will prompt to in...

Page 8: ...input figure confirm input and return back setup interface by pressing ENTER button press ESC button to cancel input and return back setup interface the input numerical value is between 1 and 32 Opti...

Page 9: ...e installed location LED NAME DESCRIPTION GREEN POWER Light when Power on the device RED GSM LED Status Connection State Flashing ON for 100ms and OFF for 100ms SIM Card not found Flashing ON for 500m...

Page 10: ...ed NC not connected PIP Connected to TrackSo Server or not CONT connected NC not connected LOG no of data points stored in devices incase of no interet 6 If the GSM light starts flashing 5 times then...

Page 11: ...p right of the screen and click on Event Ingestion Logs in the dropdown 10 Check if there is some log generated at the time of installation of the TrackSo IoT Gateway device a If NO please restart the...

Reviews: