Receiving Inspection

Upon receiving the pump, it should be 
inspected for damage or shortages.   
If damage has occurred, file a claim 
immediately with the company that 
delivered the pump. If the manual is 
removed from the packaging, do not 
lose or misplace.

Storage

Any product that is stored for a period 
longer than six (6) months from the 
date of purchase should be bench 
tested prior to installation.  A bench 
test consists of,  checking the impeller 
to assure it is free turning and a run 
test to assure the motor (and switch 
if provided) operate properly.  Do not 
pump out of liquid.

Location

Locate pump as near as possible to the 
liquid being pumped. Do Not place pump 
more that 25 feet above the surface of the 
liquid supply. 

Be sure pump is level. Mount pump 

firmly so not to move due to vibration. 

Permanently grout onto a cement 

foundation, flex coupled and v-belt 

driven units. Flex coupled units should 

be realigned after grouting to eliminate 

excessive wear on the coupling.

A minimum of 18 inches in front of pump 

case to permit easy removal and access to 

the interior of the pump. On v-belt units, 

allow a minimum of 10 inches at the shaft 

end to permit easy removal of pedestal or 

rotating assembly.

Controls

Be sure the electrical specification of 
the control selected properly match the 
electrical specifications of the pump.

Motor Connection

All wiring of motor and control, overload 

protection and grounding should be in 

accordance with the National Electrical 

Code, State and Local codes. Make motor 

connection per label located on motor or 

motor manufactures manual.

Rotation

All units rotate “clockwise” as viewed 

from shaft end of pump. It is necessary 

to slide one half of the flex coupling back 

when checking rotation to eliminate the 

possibility of unscrewing the impellers 

which are threaded on the shaft.

Suction

 CAUTION! - Pump should not 

 be operated without a suction 

 strainer to prevent foreign 

 matter from being drawn into 

 impeller. The strainer should be 

 cleaned regularly.

The use of pipe the same size as the 

port size is highly recommended. Using 

a smaller pipe line can cause internal 

damage. Make sure all lines have air-tight 

joints. The smallest air leak in the suction 

line may prevent the pump from priming. 

All horizontal suction lines should slope 

up to the pump to avoid trapped air 

pockets. All piping should be properly 

supported.

Discharge

Connect discharge hose or pipe to the 

discharge port. Make sure all lines have 

air-tight joints.

Priming

Remove pipe plug (15) in top of body 

(16) and fill the pump body completely 

with solids free liquid. In freezing weather 

prime pump with warm water.

 DO NOT operate pump without 

 priming first. Operating dry will 

 damage seal.

Starting

To start pump, apply power to motor 

per the Motor or Engine manufacture’s 

instructions.

Shutdown

Discontinue operation by stopping the 

engine as stated in Engine Manual or by 

disconnecting electric power to motor. It 

is recommended to drain  and flush pump 

if pump has been operating in freezing 

weather.

Service

 

Turn off and lock out power before 

servicing pump.

Check Valve

Disconnect suction piping  and remove 

hex nuts (30), lockwashers (31) and 

suction flange (22). Remove gasket 

(18), weights (17), (19), screw (20) and 

lockwasher (21) and replace if worn or 

damaged.

To replace, the 

HINGE

 section of gasket is 

at the 

TOP

 and the 

LARGE

 weight is on the 

pump side of gasket.

Body, Volute & Impeller

Disconnect suction and discharge piping. 

Remove hex nuts (4) and lockwashers (5) 

then remove body (16), o-ring (9) and seal 

plate (6) from pedestal (25). 

Pull volute (13) and gasket (14) from seal 

plate (6). Remove cap screw (12) and 

washers (32). Unscrew the impeller (11) 

from shaft (23) in the right hand direction. 

Take note of the size and quantity of 

shims (10) & (29) used. To replace lip seal 

(26), press out of seal plate (6).

To reassemble, use the required number 

of shims (10) and (29) to result in an 

impeller-to-volute clearance of .010”  to 

.020”.

Receiving, Installation & Service

PF10ICU   

 

 

 

 

              

    Self-Priming Universal Pumps

Summary of Contents for PF10ICU

Page 1: ...877 24PUMPS www powerflopumps com ISP No PF10ICU 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PF10ICU 2 x 2 Universal Drive Frame Mtd...

Page 2: ...n usage and location Installation and servicing is to be conducted by qualified personnel only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Always we...

Page 3: ...ss 30 SHAFT Stainless Steel SHAFT SLEEVE Stainless Steel IMPELLER Open trash type dynamically balanced Material Cast Iron Class 30 O RINGS Buna N HARDWARE Steel Stainless Steel PAINT Air dry enamel SE...

Page 4: ...stems 877 24PUMPS www powerflopumps com 4 Dimensions PF10ICU Self Priming Universal Pumps Model Weight PF10ICU 88 lbs Not for pumping flammable liquids or hazardous materials that is not compatible wi...

Page 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 Performance PF10ICU Self Priming Universal Pumps...

Page 6: ...t be operated without a suction strainer to prevent foreign matter from being drawn into impeller The strainer should be cleaned regularly The use of pipe the same size as the port size is highly reco...

Page 7: ...urface of stationary Press over shaft and into seal plate 6 Oil inner surface of rotating member and with lapped surface facing pedestal slide rotating member onto shaft until lapped faces of stationa...

Page 8: ...4PUMPS www powerflopumps com 8 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 1 PF10ICU...

Page 9: ...00 Lg Stainless 13 1 Volute Cast Iron STD PFCI10CCEVOL Volute Bronze Optional PFBRZ10CCEVOL 14 1 Volute gasket Rubber 90x 73x4 5mm PF019245 15 1 Pipe plug 1 25 NPT 16 1 Body Cast Iron PFCI10CCETNK Ch...

Page 10: ...g cap PF019845 37 1 Outer Bearing 6207ZZ 72mm OD PF019847 38 1 Inner Bearing 6206ZZ 62mm OD PF019846 42 4 Lockwasher 5 16 stainless 43 4 Hex screw 5 16 18 x 1 00 Lg stainless Repair Kits Check Valve A...

Page 11: ...ime pump body before restarting 3 Lower suction head install foot valve and prime 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge...

Page 12: ...r act of God that has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the...

Reviews: