background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

7

Shaft Seal

Remove rotating member, spring and 

retaining ring of seal (8) from shaft 

(23). To remove stationary, remove cap 

screws (43) and lockwashers (42) and pull 

seal plate (6) from pedestal (25). Press 

stationary out of seal plate. If any part 

shows wear or damage replace complete 

seal (8). Replace shaft sleeve (28) if worn 

or damaged.

 Handle all seal parts with care. 

 Do Not damage lapped faces.

Replace seal plate (6) onto pedestal (25).

Lightly oil shaft (23) and inner surface of 

stationary. Press over shaft and into seal 

plate (6). 

Oil inner surface of rotating member and 

with lapped surface facing pedestal, slide 

rotating member onto shaft until lapped 

faces of stationary and rotating member 

are together. 

Replace the rest of the seal. Replace shims  

(10), (29) and impeller (11), making sure 

that spring is properly seated against 

impeller.

Pedestal & Shaft

Remove capscrews (34), lockwashers 

(33) and bearing cap (36) from pedestal 

(25). Remove  shaft, slinger and bearing 

assembly. To replace bearing (37) remove 

retaining ring (35) and slinger (2). Press off 

bearings (37) and (38) from shaft (23).

REASSEMBLE REMAINDER OF PUMP IN 

OPPOSITE ORDER. 

Receiving, Installation & Service

PF10ICU   

 

 

 

 

 

               Self-Priming Universal Pumps

Summary of Contents for PF10ICU

Page 1: ...877 24PUMPS www powerflopumps com ISP No PF10ICU 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PF10ICU 2 x 2 Universal Drive Frame Mtd...

Page 2: ...n usage and location Installation and servicing is to be conducted by qualified personnel only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Always we...

Page 3: ...ss 30 SHAFT Stainless Steel SHAFT SLEEVE Stainless Steel IMPELLER Open trash type dynamically balanced Material Cast Iron Class 30 O RINGS Buna N HARDWARE Steel Stainless Steel PAINT Air dry enamel SE...

Page 4: ...stems 877 24PUMPS www powerflopumps com 4 Dimensions PF10ICU Self Priming Universal Pumps Model Weight PF10ICU 88 lbs Not for pumping flammable liquids or hazardous materials that is not compatible wi...

Page 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 Performance PF10ICU Self Priming Universal Pumps...

Page 6: ...t be operated without a suction strainer to prevent foreign matter from being drawn into impeller The strainer should be cleaned regularly The use of pipe the same size as the port size is highly reco...

Page 7: ...urface of stationary Press over shaft and into seal plate 6 Oil inner surface of rotating member and with lapped surface facing pedestal slide rotating member onto shaft until lapped faces of stationa...

Page 8: ...4PUMPS www powerflopumps com 8 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 1 PF10ICU...

Page 9: ...00 Lg Stainless 13 1 Volute Cast Iron STD PFCI10CCEVOL Volute Bronze Optional PFBRZ10CCEVOL 14 1 Volute gasket Rubber 90x 73x4 5mm PF019245 15 1 Pipe plug 1 25 NPT 16 1 Body Cast Iron PFCI10CCETNK Ch...

Page 10: ...g cap PF019845 37 1 Outer Bearing 6207ZZ 72mm OD PF019847 38 1 Inner Bearing 6206ZZ 62mm OD PF019846 42 4 Lockwasher 5 16 stainless 43 4 Hex screw 5 16 18 x 1 00 Lg stainless Repair Kits Check Valve A...

Page 11: ...ime pump body before restarting 3 Lower suction head install foot valve and prime 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge...

Page 12: ...r act of God that has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the...

Reviews: