Power Fist 8555724 User Manual Download Page 4

4  

For technical questions call: 1-800-665-8685

V 4.0 

8555724

Lever Action Drum Pump

ASSEMBLY & INSTALLATION

1.  Attach the discharge hose (1) to the spout (7) and secure by sliding the hose clamp (3) over 

the discharge hose securing the discharge hose to the spout.

2.  In order to avoid leakage, please use sealant tape to seal the suction tubes (2 & 5) together 

when assembling. Screw the suction tube into the bottom of the body (5).

3.  Insert the suction tube of the assembled pump into the drum. Be sure to set the pump and 

the assembled suction tube so that the suction tube is at the desired depth in the drum and is 

not blocked.

OPERATION

1.  Before pumping, tighten the vent cap (26).

2.  With the suction tube submerged in the fluid, raise and lower the handle (6) to initiate the 

suction action.

3.  To stop syphoning at any time, unscrew the vent cap (26).

4.  After using the pump, position the handle in the lowered position, the liquid will drain back 

into the container.

5.  If the pump is removed from the drum, rinse it thoroughly in a liquid that is compatible with 

both the pump and the fluid being pumped.

6.  Regularly check the pump and suction tubes for leaks. Leaks in the suction line or in the 

pump housing will cause inefficient pumping and loss of prime.

DISPOSING OF THE TOOL

If your tool has become damaged beyond repair, do not throw it out. Take it to the appropriate  

recycling facility.
Dispose of waste liquids in accordance with local authority regulations.

TROUBLE SHOOTING

Problem

Cause

Remedy

Pump does not dispense fluid. Pump not able to create 

adequate suction.

Prime pump.

Pump is drawing in air, instead 

of fluid.

Tighten all connections of the 

suction tube and of the suction 

tube at the pump inlet. Use 

thread sealant tape to seal all of 

the threads before assembly.

Suction tube inlet is blocked.

Remove the suction tube 

and clean.

Summary of Contents for 8555724

Page 1: ...User Manual V 4 0 8555724 Please read and understand all instructions before use Retain this manual for future reference Lever Action Drum Pump...

Page 2: ...fore allowing someone else to use this tool make sure they are aware of all safety information WARNING The warnings cautions and instructions discussed in this instruction manual cannot cover all poss...

Page 3: ...when operating a tool Proper footing and balance enables better control of a tool in unexpected situations SPECIFIC SAFETY PRECAUTIONS 1 Contact your chemical or fluid supplier to check for compatibi...

Page 4: ...crew the vent cap 26 4 After using the pump position the handle in the lowered position the liquid will drain back into the container 5 If the pump is removed from the drum rinse it thoroughly in a li...

Page 5: ...Visit www princessauto com for more information 5 8555724 V 4 0 Lever Action Drum Pump PARTS BREAKDOWN...

Page 6: ...Seal 1 5 Body 1 6A Handle Right 1 6B Handle Left 1 7 Spout 1 8 Cover 1 9 Piston Rod 1 10 Fixing Pin 4 11 Rod Seal 1 12 Shaft 1 13 Big Washer 1 No Description Qty 14 Piston 1 15 Small Washer 1 16 Chec...

Page 7: ...Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Manuel d utilisateur V 4 0 8555724 Pompe tambour levier...

Page 8: ...urez vous qu il est avis de toutes les consignes de s curit AVERTISSEMENT Les avertissements les mises en garde et les instructions mentionn s dans ce manuel d instructions ne peuvent couvrir toutes l...

Page 9: ...r viter qu ils ne se coincent dans l outil b N utilisez pas d appareil ou d outil si vous tes fatigu ou sous l effet de drogues d alcool ou de m dicaments c N utilisez pas l outil si vous devez tirer...

Page 10: ...placer la pompe et le tube d aspiration assembl s de fa on ce que le tube se trouve la profondeur d sir e l int rieur du baril et qu il ne soit pas obstru UTILISATION 1 Serrez le capuchon de mise l ai...

Page 11: ...succion suffisante Amorcez la pompe La pompe aspire de l air au lieu du liquide Serrez tous les raccords du tube d aspiration et le tube d aspiration au niveau de l admission de la pompe Utilisez le...

Page 12: ...1 6B Poign e de gauche 1 7 Bec verseur 1 8 Couvercle 1 9 Tige de piston 1 10 Goupille de fixation 4 11 Joint de tige 1 12 Arbre 1 13 Grande rondelle 1 No Description Qt 14 Piston 1 15 Petite rondelle...

Reviews: