2.9 GPM @ 2,500 PSI Electric Wall-Mount Pressure Washer
8
For technical questions call 1-800-665-8685
8242273
V 2.9
ASSEMBLY
NOTE: When this manual refers to a part number, it refers to the included Parts List section.
1. Select an area that is firm and dry with sufficient space to work around all sides of the unit.
2. Attach swivel adapter (#13) to elbow on hose reel (#9). Ensure that swivel adapter is pointing through the cutout
section of the hose reel.
3. Install hose reel onto frame (#1) using bolts (#10) and nuts (#11).
4. Mount frame to wall using 1/4 in. screws through the holes on each leg (8 screws required, sold separately).
Note that the centre-to-centre spacing is 16 in., which is the standard distance between wall studs.
5. Install motor/pump assembly on the top plate of frame using bolts (#3) and nuts (#4).
6. Attach detergent tray (#23) to the side of frame using bolts and nuts.
7. Attach gun hanger (#8) to frame using bolt (#18) and nut (#4).
8. Place rubber grommets (#28) into the holes on the side of frame. Insert nozzles (#20, 25, 26 & 27)
into rubber grommets.
9. Attach wand (#7) to spray gun (#12).
10. Attach nozzle (#19) to wand.
11. Attach male quick coupler (#14) to spray gun.
NOTE: Use thread tape on all threaded connections to eliminate water leaks.
12. Attach female quick coupler (#15) to hose (#29).
13. Connect spray gun to hose using male/female quick couplers. Hang gun/wand assembly on gun hanger.
14. Attach free end of hose to swivel adapter on hose reel.
15. Attach nipple (#17) to elbow end of jumper hose (#22).
16. Attach discharge coupler (#16) to nipple.
17. Attach jumper hose/coupler to the discharge port of pump (#38).
18. Attach free end of jumper hose to hose reel.
19. If you are using detergent:
a. Install clear hose (#24) onto chemical injector barb on pump.
b. Install strainer (#21) on the other end of clear hose.
c. Insert strainer end into detergent container (sold separately).
20. Ensure that all parts are installed properly and are securely tightened.
OPERATION
CONNECTING TO WATER SUPPLY
Water is supplied to the pump from an external source, normally a garden hose. To safely and efficiently use the
pressure washer, follow this procedure:
1. Connect the water hose (not supplied) to the inlet swivel ring at the water tap.
NOTE: The hose should not be longer than 25 feet to avoid pressure-drop related problems.
2. The water supply should be pressurized (not exceeding 125 PSI).
NOTE: If the water is used from an open source, use extra screens and a filter to remove all grit
and contaminants.
3. A water supply must meet the following specifications:
a. For proper performance, the supply water flow must be 1.5 to 2 times what the pump requires. For example,
if the unit is rated at 3 gallons per minute (GPM), then the supply water flow should be 4.5 to 6 GPM.
b. Do not allow the inlet water temperature to exceed 65°C (149°F). Water that exceeds this temperature can
damage the pump seals, causing crankcase oil to mix with water flow.