SD300 SERIES
POWER ELECTRONICS
16
TECHNICAL CHARACTERISTICS
3.
TECHNICAL CHARACTERISTICS
SD300 SERIES
INPUT
Power ranges
0.4kW
–
2.2kW 230V
–
Single Phase
0.4kW
–
22kW 230V
–
3-Phase
0.4kW
–
30kW 400V
–
3-Phase
Voltage range
230V: 200-240V Single Phase / 3-Phase (-15%/+10%)
400V: 380V-480V 3-Phase (-15%/+10%)
EMC Filter
C2 (First environment)
C3 (Second environment)
OUTPUT
Overload capacity
150% for 60sec. (Heavy duty)
120% for 60sec. (Normal duty)
[2]
200% for 3sec. (Heavy Duty)
Control Method
V/f, Slip compensation, Sensorless vector, PMSM VC
[1]
Frequency Setting Resolution
Digital command: 0.01Hz / Analog command: 0.06Hz (maximum frequency: 60Hz)
Frequency Accuracy
1% of the maximum output frequency
V/F Pattern
Linear, Quadratic, User V/F
Output frequency
0-400Hz (Sensorless: 0-120Hz)
Torque Boost
Manual/Automatic torque boost
OPERATION
Operation Mode
Keypad / Terminal / Communication option selectable
Frequency Setting
Analog: -10~10[V], 0~10[V], 4~20[mA] / Digital: Keypad, Pulse train input
Operation Function
PID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse
direction rotation, Speed search, Power braking, Leakage reduction, Up-down operation,
DC braking, Frequency jump, Slip compensation, Automatic restart, Automatic tuning,
Energy buffering, Flux braking, Fire Mode
Input
Multi-function Terminal
IP66 degree: 5 DIs
IP20 degree: 7 DIs
NPN (Sink) / PNP (Source) Selectable
Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation,
Multi-step frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle,
low, DC braking at stop, 2nd motor select, Frequency up/down, 3-wire operation, Change
into normal operation during PID operation, Change into main body operation during
option operation, Analog command frequency fixing, Acceleration/deceleration stop etc.
Selectable
Analog Input
V1: -10~10V, selectable V2: 0~10V/I2 4~20mA
Pulse Train
0~32kHz, Low level: 0~2.5V, High level: 3.5~12V
Output
Open Collector Terminal
Fault output and drive
operation status output
Less than DC 24V 50mA
Multi-function Relay
(N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A
Analog Output
Selectable 0~12Vdc/0~24mA Frequency, Output current, Output voltage, DC stage
voltage etc. selectable
Pulse Train
Maximum 32kHz, 10~12 [V]
PROTECTIVE
FUNCTION
Trip
Over current trip, External signal trip, ARM short circuit current trip, Over heat trip,Input
imaging trip, Ground trip, Motor over heat trip, I/O board link trip, No motor trip, Parameter
writing trip, Emergency stop trip, Command loss trip, External memory error, CPU
watchdog trip, Motor normal load trip, Over voltage trip, Temperature sensor trip, Drive
over heat, Option trip, Output imaging trip, Drive overload trip, Fan trip, Pre-PID operation
failure, External break trip, Low voltage trip during operation, Low voltage trip, Safety A(B)
trip, Analog input error, Motor overload trip.
Alarm
Command loss trip alarm, overload alarm, normal load alarm, drive overload alarm, fan
operation alarm, resistance braking rate alarm, number of corrections on rotor tuning error
Momentary Power Loss
HD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage,
rated output) HD above 15ms (ND above 8ms): Automatic restart operation enable
ENVIRONMENT
Cooling Type
Forced fan cooling structure
Protection Degree
IP20/UL Open (Default), UL Enclosed Type 1 (Option), IP66/NEMA 4X (Option)
Ambient Temperature
IP20:
HD: -
10~50˚C (14~122˚F) / ND:
-
10~40˚C (14~104˚F) [However, it is recommended to
use load below 80% when using at 50°C under light load]
IP66:
HD: -
10~40˚C (14~104˚F)
Storage Temperature
-
20~65˚C (
-
4~149˚F)
Humidity
Relative humidity below 90% RH (no dew formation)
Altitude, Vibration
Below 1,000m, below 9.8m/sec
2
(1G)
Location
No corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution Degree 3 Env.)
Pressure
70~106 kPa
REGULATIONS
Global certification
CE, UL, cUL, RoHS
PCB
3C2 Conformal coating
[1] Please consult Power Electronics before the installation with this kind of motors. [2] Only available with IP20 protection degree.
Summary of Contents for SD300146
Page 1: ...VARIABLE SPEED DRIVE Variable Speed Drive Hardware and Installation Manual...
Page 2: ......
Page 3: ...Variable Speed Drive Hardware and Installation Manual Edition February 2017 SD30MTHW01CI Rev C...
Page 4: ...SD300 SERIES POWER ELECTRONICS 2 SAFETY SYMBOLS...
Page 62: ...SD300 SERIES POWER ELECTRONICS 60...
Page 65: ...www power electronics com...