Points to note when
setting up the
compressor

Examine the machine for signs
of transit damage. Report any
damage immediately to the
company retailer or helpline.

Before you put the compressor
into operation, check the oil
level in the compressor pump.

The compressor should be set
up near the working consumer.

Avoid long air lines and long
supply lines (extensions)
tripping hazard.

Make sure the intake air is dry
and dust-free.

Do not set up the compressor
in damp or wet rooms.

The compressor may only be
used in suitable rooms (with
good ventilation and an
ambient temperature from +5°
to +40°C). There must be no
dust, acids, vapors, explosive
gases or inflammable gases in
the room.

The compressor is designed to
be used in dry rooms. It is
prohibited to use the
compressor in areas where
work is conducted with sprayed
water.

Safety instructions for
working with
compressed air and
paint sprayers

Important

- Note Health & Safety

Regulations in force also No
Smoking in work area.

Compressors and lines get hot
during operation. Avoid contact!
Risk of burns!

Gases or vapours drawn in by the
compressor have to be kept free
of constituents that may cause
fire or explosions inside the
compressor.

When you disconnect the hose
coupling, hold the coupling
element in your hand to prevent
injury from the whiplashing hose.

Wear goggles when working with
the blow-out gun. Injuries may
easily result from foreign bodies
and blasted parts.

Never point the blow-out gun at
other persons and never use it to
clean clothes that are still being
worn.

Note the safety
instructions for paint
spraying!

Important! 

Note the pertinent

accident prevent regulations in
force in your area!

Never process paints or
solvents with a flash point
below 21°C.

Never heat paints or solvents.

Use personal protective
equipment including suitable
face masks in accordance with
paint/solvent manufacturer’s
instructions. No Smoking. 
Note also the information
concerning safety precautions
published by the manufacturers
of these liquids.

No Smoking is prohibited
during the spraying operation
and in the work room. Paint
vapours are highly flammable.

Make sure there are no open
fires or open lights in the work
room. Sparking machines are
not to be used.

Do not keep or consume food
and drink in the work room.
Paint vapours are harmful.

Paint Products:

Follow all

instructions on use and safety
measures in accordance with
manufacturer’s instructions.
Additional protective measures
are to be undertaken if
necessary, particulary the

GB

Read this manual carefully before putting the compressor into operation!

Technical data

Power supply

230 V ~ 50 Hz

Motor rating in kW/h.p.

1,5 / 2

Compressor speed in rpm

2850

Operating pressure in bar

8

Pressure vessel volume in litre

24

Theoretical intake rate in l/min.

210

Sound power level LWA in dB(A)

97

Sound pressure level LPA in dB(A)

87

Protection type

IP 20

Machine weight in kg

31

Anleitung PCC 210-8  16.11.2004  10:55 Uhr  Seite 5

Summary of Contents for 40.072.80

Page 1: ... Operating Instructions Compressor Art Nr 40 072 80 I Nr 01014 PCC 210 8 24 Anleitung PCC 210 8 16 11 2004 10 55 Uhr Seite 1 ...

Page 2: ...2 Please pull out page 2 Anleitung PCC 210 8 16 11 2004 10 55 Uhr Seite 2 ...

Page 3: ...3 Note the directions for use Beware of hazardous electrical voltage Beware of hot surfaces Ear muffs Anleitung PCC 210 8 16 11 2004 10 55 Uhr Seite 3 ...

Page 4: ...er plug Whenever the compressor is not being used and before carrying out any maintenance work 13 Do not leave any tools on the compressor Before you switch on the compressor make sure that all wrenches and setting tools have been removed 14 Avoid accidental starts Make sure that the switch is turned to OFF before you connect the compressor to the power supply 15 Extension cables for outdoor use U...

Page 5: ...ies may easily result from foreign bodies and blasted parts Never point the blow out gun at other persons and never use it to clean clothes that are still being worn Note the safety instructions for paint spraying Important Note the pertinent accident prevent regulations in force in your area Never process paints or solvents with a flash point below 21 C Never heat paints or solvents Use personal ...

Page 6: ...op Putting the compressor into operation Assembling the wheels 1 Fit the wheels as shown in Figure 1 Assembling the rubber buffer Fit the supplied rubber buffer to the support foot as shown in Figure 2 Replacing the oil filter and installing the air filter fig 3 Use a screwdriver to remove the oil filler plug and insert the supplied stopper 2 in the opening Important Check the oil level Screw the ...

Page 7: ...lug and fill in oil until the level of oil in the sight glass reaches the red mark Then put the cap back on the oil filler plug 1 Filter 2 Oil filler plug 3 Oil drain plug 4 sight glass Cleaning the intake filter The intake filter prevents dust and dirt being drawn into the machine This filter has to be cleaned at intervals of no longer than 300 operating hours A clogged intake filter has a consid...

Page 8: ...8 Ersatzteilzeichnung PCC 210 8 24 Art Nr 40 072 80 I Nr 01014 Anleitung PCC 210 8 16 11 2004 10 55 Uhr Seite 8 ...

Page 9: ...sedeckel 40 072 50 07 017 18 Schraube M6 40 072 50 07 018 19 Ölsichtglas Dichtung 40 072 50 07 019 20 Ölsichtglas 40 072 50 07 020 21 Rückschlagventil 40 072 50 07 021 22 Druckschalter 40 072 50 07 022 23 Manometer 40 072 50 07 023 24 Schnellkupplungen 40 072 50 07 024 25 Druckregler 40 072 50 07 025 26 Verteiler 40 072 50 07 026 27 Gegenmutter R 1 2 40 072 50 07 027 28 Dichtring Ø18x2 4 40 072 50...

Page 10: ...0 072 50 07 046 47 Kugellager 6203 40 072 50 07 047 48 Motorflansch 40 072 50 07 048 49 Schraube M5 40 072 50 07 049 50 Lüfterrad 40 072 50 07 050 51 Sicherungsring 40 072 50 07 051 52 Kugellager 6204 40 072 50 07 052 53 Dichtring 40 072 50 07 053 54 Kondensator 40 072 50 07 054 55 Mutter M8 40 072 50 07 055 56 Kolbenbolzen 40 072 50 07 056 57 Motorabdeckung 40 072 50 07 057 58 Lüftfilter 40 072 5...

Page 11: ...11 Anleitung PCC 210 8 16 11 2004 10 55 Uhr Seite 11 ...

Page 12: ...ektiv och standarder för artikeln ilmoittaa seuraavaa Euroopan unionin direkti ivien ja normien mukaista yhdenmukaisuutta tuotteelle N erklærer herved følgende samsvar med EU direktiv og standarder for artikkel заявляет о соответствии товара следующим директивам и нормам EC izjavljuje sljedeću uskladjenost s odredbama i normama EU za artikl declarå urmåtoarea conformitate cu linia direc toare CE µ...

Page 13: ...ve to the demand to return electrical devices As an alternative to returning the electrical device the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished This can also be done by handing over the used device to a returns center which will dispose of it in accordance with national commercial and industrial waste management legislation This do...

Page 14: ...advice regarding repairs parts However any parts needed after expiry of the guarantee period will be chargeable This guarantee is no way affects your statutory rights Exceptions The guarantee does not cover natural wear and tear of the device or for damage occurring during transport neither does it cover damage which results from non adherence to the operating instructions or from incorrect instal...

Reviews: