OPTIONAL EXTRAS - Page 3
The following range of Potterton system controls are also
available and further information will be provided on
request.
Electronic Programmer E.P. 2001, E.P. 3001, E.P.
4001, E.P. 6000.
Programmable Electronic Thermostat PET 1.
ACCESSORIES
Thermostatic Radiator Valve Myson
Electronic Cylinder Thermostat PTT2
Electronic Room Thermostat PRT2
Spring Return Zone Valve PMV2
Spring Return Diverter Valve PMV3
INSTALLATION DATA - Page 3
The installation of the boiler must be in accordance with the
latest relevant requirements of the Gas Safety (Installation
and Use) Regulations 1984, local building regulations, lEE
Wiring Regulations and the Byelaws of the Local Water
Undertaking.
Detailed recommendations are contained in the following
British Standards and Codes of Practice.
B56798, BS5440 Part 1, BS 5482 Part 1
B55440 Part 2 BS5449 Part 1
B55546 B54814 B56891
BUILDING REGULATIONS 1985.
MODEL WATER BYELAWS.
BRITISH GAS PUBLICATION DM2.
GAS SAFETY (INSTALLATION AND USE) REGULATIONS
1984.
BUILDING STANDARDS (SCOTLAND)
REGULATIONS.
BOILER DIMENSIONS - Page 3
FIG. 1
Boiler
50e
60e
80e
100e
Dimension ‘A’
350
350
425
425
(MM) ‘B’
110
110
150
150
‘C’
103
103
143
143
‘D’
90
107
107
107
Flow/Return
22mm
22mm
28mm
28mm
Connections
Copper
Copper
Copper
Copper
*NOTE
IF PIPEWORK IS TO BE RUN DOWN THE BACK OF THE BOILER
THE NORMAL CLEARANCE OF 25mm BETWEEN THE REAR OF
THE BOILER AND WALL CAN BE INCREASED TO 35mm IF DESIRED
BY INVERTINGTHE BOILER MOUNTING PLATE DURING
INSTALLATION
Dimensions in brackets apply when the mounting plate is inverted).
SITE REQUIREMENTS - Page 3
These boilers are not suitable for external installation and
should not be fitted directly above a cooking appliance. The
appliance may installed in any room except a cellar or
basement. Particular attention is drawn to the requirements
of the current I.E.E. Wiring Regulations and in Scotland, the
electrical provisions of the Building Standards applicable in
Scotland with respect to the installation of the appliance in a
room containing a bath or shower.
Where a room-sealed appliance is installed in a room
containing a bath or shower, any electrical switch or
appliance control, utilising mains electricity should be so
situated that it cannot be touched by a person using the bath
or shower.
Summary of Contents for PROFILE LPG 100e
Page 4: ...SITE REQUIREMENTS Page 4 FIG 2 GENERAL ARRANGEMENT ...
Page 10: ...TECHNICAL DATA Page 10 FIG 7 FULLY PUMPED SEALED SYSTEM ...
Page 20: ...COMMISSIONING Page 20 FIG 26 FUNCTIONAL FLOW DIAGRAM HONEYWELL FIG 27 BOILER WIRING DIAGRAM ...
Page 23: ......
Page 25: ......
Page 28: ...Publication No 559472 01 92 SERVICING INSTRUCTIONS Page 26 FIG 30 FAULT FINDING CHART ...