9. Flow Diagrams – Page 26
BB45000B
Timer
Live
Room Stat
T3
T2
T6
PL2-1
PL2-3
PL2-2
F2
T1A
F1
T1A
PL6-11
Standby
Switch
(User
Control)
BN
BN
PL5-3
PL5-1
PL4-5
O/H
Stat
WH
BL
BL
WH
PUMP
Neutral (75)
PL7-1
PL7-2
Temp
Sensor
Electronic Control
Thermostat
Pump overrun
Timer
Flame Detector
Start Up Latch
Ignition Timer
RELAY RLP
RELAY RLP RELAY RLL RELAY RLT
PL6-9
PL6-8
PL6-3
PL6-2
PL6-5
PL6-7
BK
RD
WH
GY
OR
PK
Flame LED
Lockout LED
PL6-4
PL6-1
B L
B L
Reset Switch
(Located On
User Control
Unit)
PL2-4
RLT
RLT
T1-T5
PL4-3
PL4-4
RLF
Main Gas Valve
Pilot Gas Valve
Spark Generator
Ignition
Electrode
PL6-12
RLP
Gravity
Link
Mains Transformer Tx1
20v
20v
B L
RLP
RD
BN
Y L
Neutral
BL -BLUE
BK - BLACK
BN - BROWN
PK - PINK
RD - RED
WH - WHITE
YL - YELLOW
GY - GRAY
OR - ORANGE
Flame Sensing
Electrode
WH
These Products Are
Located On The User
Control Unit