Potterton FSB 30 HE User Manual Download Page 7

5.0 Fault Finding

7

© Baxi Heating UK Limited 2010

5.1

Check List

In the unlikely event you have a problem with your boiler

please check the following. 

1. Is the electricity supply to your boiler switched on ?

If so the Green ‘Mains On’ (     ) light will be lit.

2. Is the Red flame failure light (    ) lit?

Yes - Reset as described in section 2.2.

No - Continue below

3. Is the gas supply turned on?

4. Is the programmer or timer switch set to On? Refer to

the instruction booklet supplied with these items for

correct setting and operation.

5. Is the temperature control on the boiler set high

enough?

6. Are all system controls such as room and cylinder

thermostats set high enough? 

7. Are the thermostatic radiator valves set high enough?

Contact your Installer

If you have followed the steps in this simple checklist but

your boiler still does not operate contact your installer.

Any repairs to the boiler will usually be the responsibility

of the Installer during the warranty period.

Installer Help-line

Should your installer need assistance he/she can contact

our trade support help-line for diagnostic and remedy

advice.

If you smell gas

Do not operate light switches
Do not operate any electrical equipment
Do not use a telephone in the hazardous area
Extinguish any naked flame and do not smoke
Open windows and doors in the hazardous area
Turn off the gas supply at the meter
Warn any other occupants and vacate the premises
Telephone the National Gas Emergency Service on:-
0800 111 999

Faulty boiler

If it is known or suspected that a fault exists 
on the boiler, it must not be used until the fault 
has been corrected by a competent person.

Warning !

Summary of Contents for FSB 30 HE

Page 1: ...er Guide and Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Promax FSB 30 HE Floor Standing Fanned Flue Condensing Boiler You can rely on ...

Page 2: ...g address The Company Secretary Baxi Heating UK Ltd The Wyvern Business Park Stanier Way Derby DE21 6BF Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages This product has an energy rating A on a scale of A to G For more information see www boiler...

Page 3: ...h for frost protection 1 4 In Operation 1 The Promax FSB 30 HE is a high efficiency condensing boiler In common with other condensing boilers its exceptional efficiency means the flue gases are cooled to such an extent that a plume of water vapour is often visible at the outside flue terminal The amount produced depends on system design product use and outside air temperature but it is not harmful...

Page 4: ...e shut down the boiler see Section 1 2 and consult your Installer as an appliance or system fault is indicated 2 2 Resetting 1 Allow the boiler to cool if hot 2 Hinge down the facia cover 3 Press the Reset Button Fig 3 4 If the boiler will not reset see the LED Fault Indication Label on the inside of the facia cover 5 Further fault finding is described in Section 5 1 Check List Low High Reset Fig ...

Page 5: ...r is installed in a compartment do not use it for storage purposes 6 Flammable materials must not be stored in close proximity to your boiler 7 Avoid skin contact when your boiler is in operation as some surfaces may get hot e g pipework 8 Ensure that the flue terminal outside the house does not become damaged or obstructed particularly by foliage 9 It is important that the condensate drain system...

Page 6: ...ements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Body 0086 Ref 86 BL 647 For GB IE only 4 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on t...

Page 7: ...act your Installer If you have followed the steps in this simple checklist but your boiler still does not operate contact your installer Any repairs to the boiler will usually be the responsibility of the Installer during the warranty period Installer Help line Should your installer need assistance he she can contact our trade support help line for diagnostic and remedy advice If you smell gas Do ...

Page 8: ...annot be repaired or is uneconomic to repair The warranty runs for 12 months from the date your product is installed What this warranty does not cover Repairs to boilers which haven t been installed and commissioned properly and as set out in the installation instructions this includes the need to flush the system effectively and add a suitable corrosion inhibitor Any damage caused by hard water s...

Reviews: