(3) Honeywell Control solenoid
valve failed.
Check solenoid using
procedure given in
Figure 16
.
If solenoid valve has failed;
replace as described in A(3).
Page 20
Service Section – Page 21
CONDITION
POSSIBLE CAUSE
REMEDY
(4) Thermostat out of
calibration or faulty
Check thermostat using
procedure given in
Figure 17
.
If faulty, replace thermostat as
detailed in Maintenance
Instructions, Section7 .f.
(5) Blocked main burner
injector
Clean or replace injection as
detailed in Maintenance
Instructions Section 7.a.
(1) Thermostat out of
calibration or faulty.
Remedy as in item C(4).
D. Main burner fails to shut
down when water reaches
predetermined temperature
(2) Dirt on valve seat of
Honeywell control.
Clean the valve seat as
follows:-
(a) Remove the solenoid valve
and the plate beneath as
described in A(3).
(b) Clean the valve seat and
the valve chamber.
(C) Re-assemble in the
reverse order.