Change valve
The change valve assemblies control the hydraulics
for the front crossboard and wing sections. Their
purpose is to distribute the pressure of the same
hydraulic outlet to the front crossboard cylinders or
wing section lift cylinders depending on the position
of the cultivator (work or transport position).
It is advisable to lubricate the change valve shafts
with oil before the season and before long-term
storage.
Change valve control rod
•
The total movement range of the change valve is about 90 degrees
(45 degrees in both directions).
•
To adjust the control rod, lift the cultivator on its wheels so that the turning
lever assembly of the control valve is turned backwards.
•
Open the lock nuts of the control rod ball joint.
•
Detach the ball joint from the change valve turning lever and adjust
(extend or retract) the control rod as necessary.
•
Attach the ball joint to the turning lever and lower the cultivator on its tines.
•
Now the turning lever assembly is turned forwards. Test the operation
of the front crossboard.
•
If the front crossboard operates correctly, secure the lock nuts of the control
rod. Otherwise, perform the adjustment procedure again.
Summary of Contents for MAGNUM PLUS 1000
Page 3: ...3 1 INTRODUCTION Intended use Technical specifications ...
Page 6: ...6 2 SAFETY GUIDELINES Warnings Transport on roads ...
Page 22: ...22 4 HARROWING a General b Driving lines ...
Page 27: ...27 Lubrication points One time in a season Every week Two times in a week ...
Page 34: ...34 6 WARRANTY ...