![POSMicro Datalogic PowerScan D7100 Manual Download Page 40](http://html1.mh-extra.com/html/posmicro/datalogic-powerscan-d7100/datalogic-powerscan-d7100_manual_1582659040.webp)
LED and Beeper Indicators
Product Reference Guide
29
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 100 milliseconds
to 25.5 seconds (0.1 to 25.5 seconds) in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good
read LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result
with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020,
etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix E, Keypad
represent-
ing the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
Table 3
for some examples of how to set this feature.
Table 3. Good Read LED Duration Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until next
trigger pull (000)
200ms
1500ms
2500ms (2.50 sec.)
2
Divide by 100 (and pad with
leading zeroes)
000
002
015
025
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
Appendix E, Keypad
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘0’, ‘2’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
All manuals and user guides at all-guides.com
Summary of Contents for Datalogic PowerScan D7100
Page 11: ...8 PowerScanTM PD7100 Corded All manuals and user guides at all guides com...
Page 15: ...Introduction 4 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 88: ...All manuals and user guides at all guides com...
Page 345: ...Symbologies 334 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 349: ...338 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 367: ...356 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 371: ...360 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 373: ...362 PowerScanTM PD7100 Corded 6 7 8 9 A B C All manuals and user guides at all guides com...
Page 374: ...Product Reference Guide 363 D E F All manuals and user guides at all guides com...
Page 375: ...364 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...
Page 389: ...378 PowerScanTM PD7100 Corded NOTES All manuals and user guides at all guides com...