Whenever a telephone pedestal is placed within 2 meters (6 feet) of a power utility pole having a
vertical multi-grounded neutral wire (MGNV)
with impedance less than 25 Ohms
, it is highly
recommended to also bond the enclosure (cabinet or pedestal) to the multi-grounded neutral wire.
Figure 17: Grounding and Bonding next to Power Utility Pole
Each BRX-XLR unit mounted on a pole or installed directly on a strand are to have an effective
ground. It is highly recommended to bond all lead sheathed cable and the shields of plastic sheathed
cable together and bond to the grounded bonding ribbon.
Figure 18: Grounding and Bonding Strand-Mount Units