TX-3700 series Technical Manual 26
CR2 CONTROL – JP6 & 7
STATUS OF JP6 & 7 ON SOLDER SIDE CR2 CONTROL
1-2 Short
FOR XP (CR2 control by printer)
2-3 Short
FOR TX (CR2 control by Onboard)
CMOS SETTING – JCMOS
STATUS OF JCMOS ON SOLDER
SIDE
STATUS
1-2 Short
NORMAL OPERATION
2–3 Short
Clear COMS
JP10 : Model Select
STATUS OF JP10 ON SOLDER
SIDE
STATUS
1-2 Short
FOR XP
2–3 Short
FOR TX
‧
‧
‧
‧
JP12 : CR Select
STATUS OF JP12 ON SOLDER
SIDE
STATUS
1-2 Short
FOR 12V CR
2–3 Short
FOR 24V CR(XP Model only)
JP13 : Model Select
STATUS OF JP12 ON SOLDER
SIDE
STATUS
1-2 Short
FOR XP
2–3 Short
FOR TX