background image

 

 

Part 4 

occupied. The RS232 input port is a DB9 female connector. Connect the 
attached RS-232 signal cable to this port and one of the COM port in the host 
system. Set the RS-232 communication protocol for this port to 9600 bps, no 
parity, 8 bits, 1 stop bit with hardware handshaking. Connect the power 
adaptor to the rightmost power connector. Turn on the switch in the front side 
of the base. 
For PD-300U model: 

 

The RJ45 type modular connector is for internal use and is also already 
occupied. Connect the “B” type connector of the interface cable to “USB” in 
connector area and the “A” type end to USB port of the host. Insert the 2 pin or 
3 pin power connector from either 12 V AC or +24 V DC power adaptor to 
the“12 V DC In” or “+24 V DC In” jack in the connector area. Insert either 
end of the power cable to “+24 V DC Out” jack in the connector area and 
insert the other end to the power connector of Posiflex POS printer if needed. 
Be sure to hear a click at each connection to obtain a firm contact. You may 
now place the base on a horizontal surface and prepare to power on and adjust 
the direction of the display head for best viewing effect in application. 

 

 
PD-302: 

1.

 

Aim  the  bottom  center  cavity  of  PD302  series  toward  the  latch  stub  at 
rear of TP series main unit as circled in the right picture. 
Then  aim  both  metal  and  plastic  hooks  at  rear  of  the 
PD302 series toward the suitable ventilation openings 
on top rear of the main unit. Please use a phillips head 
(“+”  sign)  screw  driver  to  fasten  the  screws  on  the 
metal hook but not to overdo it so that the metal hooks 
hold the ribs of the ventilation holes from inside. 

2.

 

Plug the DB9 female connector to the COM port with power DC supply 
from the TP series. Please remove the COM1 terminator and save it at a 
safe place for future use if COM1 is to be used for PD302. 

3.

 

Route  the  cable  to  go  through  the  notch  on  back  of  the 
stand  assembly  of  touch  terminal  as  indicated  in  the 
picture. Reassemble the main unit and stand assembly. 
(

Guidance for future un-installation:

 Please use screw 

driver  to  release  the  metal  hook  before  removing  PD302  from  the 
ventilation holes.) 
 

Metal Hook 

Plastic Hook 

Summary of Contents for PD-300 Series

Page 1: ...sulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concer...

Page 2: ...N GUIDE POWER PREPARATION FOR PD 300 PD 300U For these models of customer display it need to be powered by a separate power adaptor Therefore there is no need for any operation in the POS host system The power adaptor for PD 300 supplies 12VAC the power adaptor for PD 300U can either be the 12V AC one or the 24V DC power adaptor for Posiflex POS printer and to support the printer through use of on...

Page 3: ...tem during power off to adjust the internal jumper to supply 5 V DC to the COM port selected for the customer display following guide from relevant technical manual FOR PD 303 There are 2 cables from the PD 303 for application in a host computer system as shown in the right picture The cable with a DB9 female connector is for connection to the COM port of the system for data transmission Plug the ...

Page 4: ...to obtain a firm contact You may now place the base on a horizontal surface and prepare to power on and adjust the direction of the display head for best viewing effect in application PD 302 1 Aim the bottom center cavity of PD302 series toward the latch stub at rear of TP series main unit as circled in the right picture Then aim both metal and plastic hooks at rear of the PD302 series toward the ...

Page 5: ...7 PD 307U installation operation the HT main unit or PB system has to be opened with sufficient precautions First push in the circled knobs on both sides as in the right picture to remove the back cover Take out the arrow pointed pole cover from it 2 Prepare a piece of clean soft clothe of appropriate size in front of the HT system to prevent damage to the display panel Turn the display panel to s...

Page 6: ...rectangular installation holes A on bottom of HT or PB chassis from the right corner with the pole display slightly inclined to the left as in the upper picture at right Please note that both bottom locking lugs A should be completely inserted and come out of the bottom plate of HT or PB system as emphasized by an arrow in the enlarged portion in lower right 6 Please always keep a gentle pressure ...

Page 7: ...ace cable of PD 307 or PD 307U to appropriate port in system connector area Then close the back cover of the system PD 308 PD 308U 1 To install PD 308 or PD 308U onto FT series host system the back cover of FT system base has to be opened First push in the circled knobs on both sides as in the right pictures to remove the back cover 2 Remove the pole cover on rear edge of the base top cover of FT ...

Page 8: ...ture DRIVER INSTALLATION FOR RS 232 INTERFACE MODELS For direct I O control over the serial interface RS232 models you have to send all commands listed later in this manual under communication protocol 9600 bps none parity 8 data bits 1 stop bit with hardware handshaking on CTS signal to the COM port used No other driver installation is required FOR USB INTERFACE MODELS Copy the driver and library...

Page 9: ... set in OPOS Control Manager device name PD3x Line Display in the top row For RS 232 models select the COM port in the 3rd row and set baud rate to 9600 in 4th row as in the left sample screen below Select USB in 3rd row for USB interface models as in the right sample picture below ...

Page 10: ... H x 10 98 mm V Dot size 1 12 mm H x 1 12 mm V Dot pitch 1 22 mm H x 1 22 mm V Display head size for PD 302 303 305 PD 306 308 217 mm W x 80 5 mm H x 28 5 mm D 196 7 mm W x 57 5 mm H x 39 6 mm D Pole height PD 306 8 200 mm Input power type DC Input voltage 5 V Current consumption 500 mA max Operation temperature 0ºC 50ºC 32ºF 122ºF Storage temperature 10ºC 60ºC 14ºF 140ºF Display window size for P...

Reviews: