background image

 

 

Part 2 

ALERT TO OUR HONORABLE CUSTOMERS: 

Please always read thoroughly all the instructions and documents 

delivered with the product before you do anything about it. Don’t 
take any premature action before you have a full understanding of 
the consequences. 

This product contains inside a Lithium battery and maybe also a 

sealed type Lead acid battery if the  UPS battery option is ordered. 
Please always follow local environmental protection laws / 
regulations for disposal of used batteries and always replace only 
with battery of same type. 

If you have an UPS battery installed in the product: 

² 

Temperature above 

40°C must be strictly avoided

 as it 

could cause termination of battery life and unexpected result 
even if the battery is not in work. 

² 

Do not

 power off the system just by shutting off the AC 

power leaving the battery supporting the whole system till 
completely exhausted. 

Repeatedly using it up or improper 

maintenance reduces the battery life dramatically

² 

Always fully recharge the battery at least once every 3 
months if the battery is not connected. 

² 

Always 

disconnect the UPS battery

 from the system if the 

system is to be left OFF for more than 

72 hours

 to prevent 

possible damage. Only connect the UPS battery back right 
before you are going to re-power on the system. 

² 

Replace the battery as soon as the monitoring software 
indicates the battery is out of service. Attempt to recharge a 
dead battery is 

dangerous

² 

A separate battery monitor is not required for this series. 

DAILY MAINTENANCE GUIDE 

For regular cleaning of the Jiva systems, please use only soft haired 

brush or dry soft cloth. You may use moist soft cloth to remove stains when 
necessary. Apply only proper amount of mild neutral detergent for obstinate 
stains. Please pay attention that never use Acryl dissolving solvent or 
Polycarbonate dissolving solvent. You may apply ammonia-based glass 
cleaner only on the screen surface. 

 
 

Summary of Contents for Jiva LT-5600

Page 1: ...ta or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware c...

Page 2: ...ystem till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are g...

Page 3: ...esistive type leading edge Infra Red type optional touch panel that endures 35 million touches min at same spot for Jiva TP only i Long life touch panel that endures 35 million touches at same spot for Jiva TP only j Spill proof water resistant structure allowing easy cleaning k Easy maintenance construction l Various I O ports supported including 1 one PS 2 KB port 2 one PS 2 mouse port 3 4 seria...

Page 4: ...5800 or up to 2GB for TP LT 8000 b Infra Red type touch panel durable for 50 million touches min at same spot for Jiva TP only c Audio amplifier circuit for TP LT 5600 5700 5800 and a pair of speakers in cable cover area d Side mount upgrade kit among Security upgrade kit KP100 covering keypad and optional KB interface MSR Security upgrade kit SD100 covering options of USB interface MSR and iButto...

Page 5: ...and then disconnect every cable properly before separation of main unit and the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port or the CR port Please also note that the fixing screws have to be loosened free prior to disconnection such as the COM ports or the LPT port Please always hold the connector he...

Page 6: ... open Take the bottom plate up and the inside of the base stand looks like this in the left picture below However there will be no HDD in base for TP LT 5600 5700 and its picture is shown at right Step A Prepare a soft clean flat surface such as a piece of cloth on the desk to seat the front surface of main unit Step C Slide the base stand assembly to this direction to separate Step B Press the Lo...

Page 7: ... wall material Drywall concrete solid wood etc Consult with your contractor if it is necessary A fully equipped system may weigh up to 10 kgs or 22 lbs Take the separated bottom plate and remove the 4 rubber feet to work as the wall mount bracket Fix this bracket to wall at the 3 arrowed holes in the right picture with proper materials Release the base box from the base stand by removing the 3 scr...

Page 8: ...of the rear connect cover from inside to remove the cover Fit the latest base of PD 2501 or LM 6201 to the rear connect cover opening For LM 6201 please first route its cable through this opening and have it pass the passage arrowed in left picture For PD 2501 please have its cable go through the normal cable exit under the joint base as in the right picture Fit 2 screws through washers to hold th...

Page 9: ...d a button cell battery socket and several jumpers for some technical settings Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops This battery socket accepts a 3 V button cell Lithium battery CR2032 required to support the system real time clock The used ...

Page 10: ...n for the advantage of several fixed predetermined connections without need for connection alteration in process the third Dongle and afterwards have to attach to the appropriate positions by use of the self adhesive tape because Jiva series supports only 2 rear top corners with hooks The Posiflex wireless connection supports various application environments from having single Dongle to control si...

Page 11: ...the total height required is 296 mm CONNECTING CABLES When later the main unit and stand assembly are to be re assembled for application please connect all required cables to the appropriate connectors Please make sure that each connector is connected to the correct port with the correct orientation Damages due to incorrect connection or orientation are not covered by product warranty Some connect...

Page 12: ... usual system management utilities such as FDISK EXE or FORMAT COM shall never be used on CF Card otherwise the boot sector of operating system itself may be damaged and causing the CF Card no longer bootable For Jiva TP LT 5800 8000 the preloaded operating system exists in the HDD in base Once the software system on HDD collapses it is possible to restore the operating system onto a physically in...

Page 13: ...ssionalized equipment The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user who either has barely limited technical knowledge of this professionalized equipment or is insufficiently equipped with necessary facilities to accomplish such a task Therefore OS installation into a system without preloaded OS is highly discouraged Posiflex sh...

Page 14: ...0 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 3 8 min for TP LT 5600 5700 5800 or 2 6 min for TP LT 80...

Page 15: ...ower Supply The operating voltage range of the power adaptor should cover the local power supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation Serial Port COM1 COM1 ser...

Page 16: ...may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the Jiva series technical manual this switch will always tu...

Page 17: ...Jiva system is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with high color In configuration of system memory for TP LT 5600 5700 5800 max 64 MB can be shared as the video m...

Page 18: ...r to disable the internal audio amplifier and connect a pair of speakers with booster or amplifier to this port Please note that this modification is a highly technical operation and should not be handled by any person else Please also note that the number and types of I O ports shown in picture above may evolve with time without notice FAN CONTROL In the preloaded OS for Jiva system there is an e...

Page 19: ... a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex Touch Terminal Manager A program named Posiflex Touch Terminal Manager and a right click sticky button tool in the program group Posiflex Tools is installed in the preloaded Windows system with a PS 2 interface touch panel control...

Page 20: ...USB Touch Tools is installed in the preloaded Windows system with a USB interface touch panel controller This program can also be obtained by download from the POSIFLEX web site 警告使用者 這是甲類的資訊產品 在居住的環 境 中 使 用 時 可 能 會 造 成 射 頻 干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...

Reviews: