![POSIFLEX Jiva KS-6215 Series Technical Manual Download Page 46](http://html1.mh-extra.com/html/posiflex/jiva-ks-6215-series/jiva-ks-6215-series_technical-manual_1582422046.webp)
KS-6215 / KS-6215I / KS-6217 series Technical Manual 5 - 10
UPS SETTING
When the system is equipped with a workable UPS battery, “Enable” will be
automatically selected to make operations running smoothly during
intermittent
power failure. When there is no UPS battery installed (or when the installed UPS
battery is detected as “dead”), “Disable” will be automatically selected to make sure
that the system immediately turns off and rejects any possible noise or the consequent
RTC CMOS setup data loss when power fails.
POWER OFF DELAY TIME
This function defines the time delay between the software power off command
in the “Start” menu and the actual power off. The count is
programmable between 1 and 255, and each count represents 1 sec delay. This
software power off command is an irrevocable process just like pulling the plug after a
certain delay to allow the shutdown procedures. So special care must be exercised in
using this software power off command. However, this command must be engaged to
turn the power off when the power switch is set to “ON Only”.
POSIFLEX USB MSR MANAGER
For systems with USB MSR on
side mount upgrade kit, the USB MSR
manager helps defining several
characteristics in output format control
for reading the magnetic stripe card.
Please find the subfolder
\Drivers\SD Series\USBMSR_xxx in
Posiflex product information CD and
execute the “SETUP.EXE” to install
the USB MSR Manager. The screen
shot of the program is similar to the top picture at right. The program will be in
“Posiflex Tools” and in “StartUp” there will be
Summary of Contents for Jiva KS-6215 Series
Page 16: ...KS 6215 KS 6215I KS 6217 series Technical Manual 2 4 ...