KS-6215 / KS-6215I / KS-6217 series Technical Manual 5 - 7
query command is received. It is advisable to take a check on the response between 1
to 10 seconds after sending the query command and to send the other query command
only after first response checked to avoid any possible ambiguity.
In this product, when the system is working on UPS battery power, the status
is indicated by LED and is detectable by software. This “operating on battery” signal
can be obtained through checking the communication status of COM1 at signal DCD
provided this signal is not engaged elsewhere (In other words, Modem is not
recommended to be used on COM1). When the system is working on AC power, the
DCD signal of COM1 is reset (value = 0). When the system is working on battery
power, the DCD signal of COM1 (BATTWK signal) is set (value = 1). The DCD
signal is obtained as the bit 7 (the most significant bit) of the I/O address 3FEh if the
COM1 address is set to 3F8h~3FFh (conventional address for COM1) in system
configuration.
AUTOMATIC POWER ON CONTROL
When the system is turned off after a successful boot up, the preset automatic
power on functions if set as below will keep monitoring for the preset conditions and
turn on the system when the preset conditions are met.
Please note that if the system is improperly turned off before a complete boot
up procedure, the above preset power on control functions will be disabled until next
turning off after a complete boot up.
ALARM CLOCK WAKE UP
To utilize Alarm Clock Wake Up function, the user should enter the CMOS
setup by pressing “Del” key at system boot up, choose for “IRQ/Event Activity
Detect” in “Power Management Setup” and make the “RTC Alarm Resume” enabled
and set the alarm to required time. Save the configuration and exit the CMOS setup
program. The Preset Power On Control will then be ready.
MODEM RING UP
To utilize Modem Ring Up function, the user should enter the CMOS setup by
pressing “Del” key at system boot up, choose for “IRQ/Event Activity Detect” in
“Power Management Setup” and make the “Modem Ring Resume” enabled and