5 - 2
B.
SETUP WINDOW
On bottom cover of the Aura series thermal printer, there is
screwed a metal plate for setup window. In this window, there is a
8 position DIP switch for printer setup. Please use proper tool to
change the switch setting when necessary. The switch position
counting starts from the nearest edge of printer. The ON direction
points to the connector area of the printer. The OFF direction
points to the power switch. The functions of each position may
evolve with the revisions of the firmware. The information below
applies to the latest version to the date of print of this manual.
This 8 position DIP switch works as following:
Switch
position
ON OFF
1
2
RS232 baud rate definition or Parallel interface
definition (ref. separate table below)
3
Even parity
None parity
4
XON handshaking
Hardware handshaking
5
Busy on “buffer full”
Busy on “off line”
6
Immediate cut
Protective cut
7
CR code effective
CR code ineffective
8
Factory internal setting
Application standard mode
Effect of positions 1 & 2 on baud rate is defined as in table
below with parity check set according to position 3, number of
data bits always set to 8, and stop bit set to 1. When the parallel
interface is used, please set both positions to ON.
SW Pos. 1
ON OFF ON OFF
SW Pos. 2
ON ON OFF OFF
Baud rate
or Interface
38400 bps /
(Parallel)
4800 bps
9600 bps
19200 bps
Switch position 3 defines the parity check regulation in
serial interface. In Aura, it is selectable between even and none.