2 - 6
port assignment setup will be required to use the USB printer as if
a normal serial printer. The procedures described below may also
be engaged any time whenever a re-assignment of the COM port
number is required. Select “Start”, “Settings”, “System”,
“Hardware”, “Device Manager” consecutively in the Windows
screen and explode the item “Ports (COM & LPT)” to find the
“Posiflex PP-7000IIUSB Thermal Printer” designated to a COM
port number as in one of the pictures below.
Click right button of mouse on this
item and select “Properties” then “Port
Settings”, please set parameters in the
right window according what the system
integrator requires with the Application
Program. A common practice is to set
“19200” for “Bits per second”, “8” for
“Data bits”, “None” for “Parity”, “1” for
“Stop bits”, “Hardware” for “Flow
control” if not specified.
Click “Advanced..” in this above window to select the
“COM Port Number” to any number as required by the
Application Program like the example screen in picture below.
Then click “OK” and finalize the device manager. After reboot,