![Posi Pin CR-R885-A Installation And Operating Instructions Manual Download Page 11](http://html1.mh-extra.com/html/posi-pin/cr-r885-a/cr-r885-a_installation-and-operating-instructions-manual_1582228011.webp)
PosiPin 9
READER’S INTERFACE
Section [007]
[007]
[007]
[007] - Default: [0]
[0]
[0]
[0]
The reader component of the PosiPin must be programmed to use
the same reader communication format as the controller.
CHECK-IN SUPERVISION
Section [008]
[008]
[008]
[008] - Default: [0]
[0]
[0]
[0]
This feature only applies when the communication format
programmed in Section
[002]
is set for Option
[1]
: 26-bit
Wiegand or Option
[2]
: 37-bit Wiegand.
When no actions are performed on the PosiPin for a period of time,
it will communicate its status to the controller every 30 seconds by
sending a code to confirm its presence (26-bit Wiegand =
255:65535; 37-bit Wiegand = 65535:65535). If the PosiPin does
not communicate its status every 30 seconds, the controller can be
programmed to generate an alarm.
Enter
Description
[0]
26-bit Wiegand
[1]
37-bit Wiegand
Enter
Description
[0]
Check-in Supervision disabled
[1]
Check-in Supervision enabled