Instruction Manual
w
PE 100-T
12
4.
As soon as final speed is reached close condensate
drain tap (1, Fig. 5) of intermediate separator (on
petrol units additionally the condensate drain tap
(2, Fig. 5) of final separator).
5.
Open filling valve (Fig. 8), wait until air escapes and
flush the compressor unit 1 to 2 minutes, i.e. let the
air escape into the surroundings.
Fig. 8
Scavenging
1
6.
Close filling valve and start promptly the filling pro
cedure. See Filling the bottles.
3.3.5. Filling the bottles
Scavenge the compressor prior to
connecting the bottle if the unit has been
put out of service for more than several
hours. See 3.3.4.
On models of 300 bar rated filling pres
sure do not attach bottles unless rated for
this pressure (note pressure stamped on
tank neck).
1.
Connect air bottle to filling valve. See Fig. 9.
Fig. 9
Connecting air bottle
The international connector (Fig. 10) is
not permitted in the Federal Republic of
Germany. In other countries it is allowed
only for pressures up to 200 bar (2,850
psi).
Fig. 10
International filling connector
2.
Open filling valve first, then bottle valve. See
Fig. 11.
2.
1.
Fig. 11
Filling air bottle
3.
Ensure that condensate drain tap (1, Fig. 12) of in
termediate separator is open. On petrol units open
additionally the condensate drain tap (2, Fig. 12) of
final separator.
Summary of Contents for PE 100-T
Page 1: ...High Pressure Breathing Air Compressors Instruction manual...
Page 2: ......
Page 39: ...Instruction Manual w PE 100 T 33...
Page 40: ......
Page 41: ...Instruction Manual w PE 100 T 35 8 ANNEX Schematic diagram Lubricating oil list Parts list...