20
♣
Important!
When connecting or disconnecting the power supply from the printer, be sure to follow
instructions below.
Use a power supply (Limited Power Supply) of DC 24V±10% and more than 1.75A.
Be careful when installing the printer in an area where there is AC line noise
.
Take the appropriate measure to protect against electrostatic AC line noise, etc
9-5. Environmental Requirements
(1) Operating
Temperature
5°C to 40°C
Humidity
10% to 90% RH (without condensation)
(2) Transport/Storage (except paper)
Temperature
-20°C to 60°C
Humidity
10% to 90% RH (without condensation)
9-6. Reliability
(1) MCBF
60 million lines (based on an average printing rate of 12.5% with paper
thickness in the range of from 65µm - 75µm)
35 million lines (based on an average printing rate of 12.5% with paper
thickness in the range of from 76µm - 150µm)
(2) Head Life
160Km
(3) Cutter Life
1.5 million cuttings (if the paper thickness is between 65 and 100µm)
9-7. Certification
(1) FCC PART15 CLASS A
(2) UL/cUL (UL 60950-1)
(3) KCC
(4) CE-EMCD (CE-EMCD Class B should use Parallel shield Cable compliant with IEEE-1284 standards)
(5) ENERGY STAR
This equipment is for indoor use only and all the communication wiring are limited to inside
of the building”