ZF3000
EXTERNAL BLIND INSTALLATION
7.
In the case of external blinds with manual drive, mark the
place for the opening for the control wire after the
installation of the package
.
8.
Uninstall the package, drill a hole with fi 12 drill in the window
frame or in the wall (depending on the installation type) for the
control wire and re-install the package into the top rail handle
.
10.
In the case of external blinds with manual drive, after
installing the blind package, put the crank pin (1.) in the
manual drive gear by placing it from the inside of the room
through the previously prepared hole in the wall or window
depending on the installation method
.
Screw the manual drive guide (2.) to the wall
...
4
3.
The installation place of wall handles should not interfere
with the proper functioning of the blind lifting and lowering
mechanisms (crank, motor). The maximum distance
between the handles should not exceed 800mm
.
5.
Install the top guide handles on the extreme edges of the
top rail
.
6.
Install the blind package into the open handles in such a way
that the "WINDOW SIDE" label with information about the
installation side is on the window side
.
4.
Screw the top rail handle to the mounted wall handle.
max. 800mm
1.
2.
9.
Close the top rail handles and tighten the screws
.
WINDOW
SIDE