8
Set Access Point Name (APN), User Name, Password. The maximum length of the APN, User name and
Password is 49 characters.
TCP/UDP address and Port number of the remote server being set, UNIT will send report to these address.
Note that only one TCP or UDP server will be used at the same time.
Set the SMS Number of the server. The unit will send reports to the server if GPRS connection is failed.
UNIT can save 900 reports (900-1) recently; Click ‘Export’ button can export them with Excel or Text format.
“Initialize ” button: clear all data in UNIT.
Request All: read out the whole existing setting from GT3100.
Request: read out the setting in the current page.
Apply: transfer the setting to GT3100 in the current pages.
Apply All: transfer the whole setting to GT3100.
Load: load the saved configuration files.
Save: save the current configuration setting to a file.
“Exit ” button: exit PC-Setup to main program.
Note that Device ID, GPRS Login and server IP/Port information need to be input correctly in order to make
the connection. If the report sending using GPRS connection fails, the report will be sent to the ‘primary’ SMS