Porter Silhouette-LG User Instructions Download Page 2

 

 

 

Silhouette Introduction  

 

Please review brief instructional setup and 
usage videos at 
www.porterinstrument.com/silhouette 

 
 
The  Silhouette  low  profile  nasal  mask  design 
provides to the Medical Health Care market a mask 
and  breathing  circuit  solution  that  will  allow  high 
visibility  to  the  medical  professional  [especially 
dentist],  and  provide  an  adhesive  based  seal  onto 
the  patient’s  face,  allowing  its  built-in  scavenging 
system to effectively remove excess/exhaled nitrous 
oxide [N2O], with minimal loss to the environment.  It 
allows  the  patient  to  receive  the  proper  amount  of 
Oxygen  and  Nitrous  Oxide  with  normal  respiratory 
effort. 
 
The Nasal Mask is placed first (adhesive lamination 
cover removed first) on to the patient's nose.  The 
Comfort Tubing is placed around the patient's ears. 
The Reusable Section is attached to the Fresh Gas 
and Vacuum Control Device connections. The Slide 
Bolo is placed to secure the Circuit at the patient's 
neck, completing a multi-point secure placement on 
the patient’s face.  A Fresh Gas Mixture of nitrous 
oxide and oxygen is delivered from the Flowmeter 
into the Circuit and into patient's nasal cavity via 
the Mask; exhalation is scavenged through to the 
Vacuum Control Device.  Disposable Section is 
disposed after use.  
 
The sight lines from the medical professional to the 
patient’s mouth (work area) created by the low 
profile are superior.   
 
The medical professional can easily manipulate the 
patient’s mouth without interference to the fit of the 
Circuit, while the patient can turn the head side to 
side in comfort, without losing the seal. 

 

 
 
 
 
 
 
 
 
 

Use  Silhouette  with  or  without  a  Bag  Tee  (see 
photos  of  Reusable  vacuum  and  fresh  gas 
attachments to Porter and Matrx flowmeters). 

 
Matrx 

 
Porter with AVS (and without Bag Tee) 

 

Please review brief instructional setup, how to 
retrofit, and usage videos at 

www.porterinstrument.com/silhouette

 

 
The Silhouette Circuit may be used with or without a 
Bag Tee.  When used with a Bag Tee (including those 
of  most  brands  of  flowmeters)  the  3-Liter  Breathing 
Bag  should  be  capped  off  using  the  Cap 
(62905510W) found in kit SIL-CONN-KIT.  The fresh 
gas  Adapter  (PA-1629-000)  in  the  kit  provides  a 
22mm  adapter  to  5-7  mm  taper  for  the  Reusable 
paratubing hose (B-5581-000).   
 
Note: Primarily, the 4 holes featured in every 
Silhouette Mask provides air intake.  Alternatively, 
patient inhalation through Silhouette Circuit (with 
Total Flow delivery of approximately 5 L/min or 
lower) will open the Emergency Air Intake EAI valve 
on a Bag Tee for supplemental air intake.   
 
Do not block the 4 holes during a procedure.

 

 
 
 

 

 

Summary of Contents for Silhouette-LG

Page 1: ...e Usable with Porter Automatic Vacuum Sw itch AVS 5000 Porter Vacuum Control Block 5501 RK Matrx Vacuum Control Device on flow meter The Quality System for Porter Instrument is Certified to ISO 13485 The scope of our registration is The design manufacture distribution and servicing of Dental Flowmeters Gas Scavenging Systems Gas Distribution Systems and Office Communication Systems for use in the ...

Page 2: ...d through to the Vacuum Control Device Disposable Section is disposed after use The sight lines from the medical professional to the patient s mouth work area created by the low profile are superior The medical professional can easily manipulate the patient s mouth without interference to the fit of the Circuit while the patient can turn the head side to side in comfort without losing the seal Use...

Page 3: ...nd of the Reusable vacuum hose 15 to the Union of the Silhouette Disposable Circuit diameter indexed and the other end to the MASK port labeled on body of the AVS 1 Attach a second vacuum hose 15 to the VAC port labeled on body of the AVS 1 then insert straight end of adapter 20 into the other end of the vacuum hose and the tapered end of the adapter into the High Volume Evacuation HVE Line 6 Vacu...

Page 4: ...3 ...

Page 5: ...7a 5068 5 8 T Adapter for In line Vacuum Block See Figure 2 18 5064 Straight Adapter for In line Vacuum Block See Figure 2 19 5065 Vacuum Tube Holder 20 A 3679 000 Adapter Black Round VAC MASK 21 PA 1630 000 Clip Strap 22 SIL SIZER 4 Silhouette Sizers 4 pack Part Numbers Silhouette 4 sizes of Mask Silhouette PD Silhouette SM Silhouette MD Silhouette LG Reorder Part Number SIL PEDO 12 SIL SM 12 SIL...

Page 6: ...gain after adjustment 8 Monitor the vacuum conditions during the procedure by observing the sight glass Note vacuum is indicated with Silhouette Circuit attached and ball pegged high in sight glass Ball float at bottom indicates no vacuum flow Repeat steps 2 through 7 to adjust vacuum flow as necessary 9 Note Adjust vacuum flow with Matrx vacuum control block with Silhouette Circuit attached Set t...

Page 7: ...e mask 11 Place the tubing over the top of the left and right ear 12 Move the slide bolo up until the circuit is snug against the patient s neck 13 Connect disposable section union diameter indexed to gas and vacuum reusable hoses SIL CONN KIT 14 Observe overall position of the patient mask and circuit for proper positioning with good mask seal and no evidence of tubing kinking Use Clip Strap on R...

Page 8: ... for 15 minutes minimum For unwrapped loading Load product into sterilizer without using wrapping packaging or cassette on to standard sterilizer rack or simple sterilizer tray This method of loading is adequate for steam sterilization For wrapped or bag pouch loading Load product into bag or wrap packaging according to sterilizer instructions Assure that the packaging is adequate for steam steril...

Page 9: ...es or 4 not installed by an authorized Parker Hannifin Corporation dealer Parker Hannifin Corporation s obligation for breach of this warranty or for negligence or otherwise shall be strictly and exclusively limited to the repair or replacement of the product or part This warranty shall be void on any product on which the serial number has been altered defaced or removed ORDERS All orders are to b...

Reviews: