13
Mounting the table (Fig. E, F)
5. Remove the table aligning pin (18) and
table insert (13) from the table.
6. Guide the table slot (14) over the saw
blade and rotate a 1/4 turn, so the slot is
perpendicular to the blade.
7.
Bag “F” -
Placing the lock knob bolts (10)
through the trunnion bracket holes (15)
as shown, lower the table onto the
trunnion bracket.
8. Place a lock knob (16) on each lock knob
bolt. Adjust the table by aligning the zero
scale mark to the scale pointer (17) and
tighten the knobs.
9. Replace the table insert (13), aligning
the indents.
10. Place the table aligning pin (18) in the
hole (19) at the front of the table, and
tighten it.
13
14
10
15
13
18
16
17
19
Fig. E
Fig. F
INSTALLING AND REMOVING BLADES
(FIG. G)
To avoid injury from accidental starting,
always turn the switch OFF and remove the
plug from the power source before moving,
replacing, or adjusting the blade.
Removing
1. Loosen the blade tension by turning the
blade tension knob (1) counterclockwise.
2. Remove the table insert (2) and remove
the table aligning pin (3) from the table.
3. Open the upper and lower wheel cover
doors (4).
4. Loosen the two Phillips screws (5) and
remove the upper blade guard (6).
5. Remove the blade (7) from the upper and
lower blade guides (8).
6. Carefully pull the blade from the side
slot (9) and from the wheels (10).
7. Swing the left side of the blade toward
you, turning the blade so it will fit through
the slot (11) in the table, and remove.
NOTE:
The available usage of blade
length is from 91-1/2 to 93-1/2 in.
(2324 to 2374.9 mm).
1
10
6
5
8
2 11
4
9
3
8
10
4
7
WARNING
!
Fig. G