  ALWAYS  USE  SAFETY  GLASSES.  Everyday  eyeglasses  are  NOT  safety 

glasses. Also use face or dust mask if operation is dusty. ALWAYS WEAR CERTIFIED SAFETY 

EQUIPMENT:

•  ANSI Z87.1 eye protection (CAN/CSA Z94.3),
•  ANSI S12.6 (S3.19) hearing protection,
•  NIOSH/OSHA respiratory protection.

Before operating this tool, carefully read and understand all instructions in 

Important 

Safety Instructions.

ASSEMBLy

Lock off trigger, disconnect air line from tool and remove fasteners from 

magazine before making adjustments or personal injury may result.

TRIGGER 

 Keep fingers AWAY from trigger when not driving fasteners to avoid accidental 

firing. Never carry tool with finger on trigger. In bump action mode (contact actuation mode) tool 

will fire a fastener if safety is bumped while trigger is depressed.
In accordance with the ANSI Standard SNT-101-2002, the PORTER-CABLE nailers are assem-

bled with a sequential action trigger. 

nOte: 

The NS150B is equipped with a selectable trigger 

allowing one trigger to choose  single sequential action trigger mode or bump action trigger 

mode. However, a bump action trigger kit may be purchased for the NS100B. For a replace-

ment trigger or to order a bump action trigger contact your authorized service center or call 

1-888-848

-

5175. 

tO ReplACe seqUentiAl tRiGGeR (ns100B only)

Trigger Removal (Fig. 2)
1.  Lock off trigger.
2.  Remove air from the tool.
3.  Remove rubber grommet (N) from end of dowel pin (M).
4.  Remove dowel pin.
5.  Remove trigger assembly from trigger cavity under the handle of the tool housing.
Trigger Installation
1.  Insert the trigger kit into trigger cavity.
2.  Ensure that trigger spring (O) is placed around the trigger valve stem.
3.  Align the holes of the trigger with the housing holes, then insert the dowel pin (M) through 

the entire assembly.

4.  Push the rubber grommet (N) onto the end of the dowel rod. 

opERATIoN

pREpARING THE TooL

Read  the  section  titled 

important  safety  instructions

  for  Pneumatic  Tools 

at the beginning of this manual. Always wear proper eye [ANSI Z87.1 (CAN/CSA Z94.3)] and 

hearing protection [ANSI S12.6 (S3.19)] when operating this tool. Keep the stapler pointed away 

from yourself and others. For safe operation, complete the following procedures and checks 

before each use of the stapler.

nOte: 

These nailers are designed to be used without oil. 

1.  Before you use the nailer, be sure that the compressor tanks have been properly drained.
2.  Wear proper eye, hearing and respiratory protection.
3.  Lock  the  magazine  release  in  the  back  position  and  remove  all  fasteners  from  the 

magazine. 

4.  Check for smooth and proper operation of contact trip and pusher assemblies. Do not use 

tool if either assembly is not functioning properly. NEVER use a tool that has the contact 

trip restrained in the up position.

5.  Check air supply. Ensure that air pressure does not exceed recommended operating limits; 

70 to 120 psi, (4.9 to 8.3 bar, 5 to 8.5 kg/cm

2

).

6.  Connect air hose.
7.  Check for audible leaks around valves and gaskets. Never use a tool that leaks or has 

damaged parts.

 

UsinG the lOCK-Off (ns100B, fiG. 1, 2)

 To reduce the risk of injury. 

AlWAYs 

wear proper eye [ANSI Z87.1 (CAN/CSA 

Z94.3)] and hearing protection [ANSI S12.6 (S3.19)] when operating this tool.

 Do not keep trigger depressed when tool is not in use. Keep the lock-off switch 

rotated to the right (OFF) when the tool is not in use. Serious personal injury may result.

 Lock off trigger, disconnect air line from tool and remove fasteners from 

magazine before making adjustments or personal injury may result.

 

The NS100B stapler is equipped with a trigger lock-off switch (J) which when rotated to the 

right, prevents the tool from actuating. When the switch is in the unlocked position, the tool 

will be fully operational. The trigger should always be locked off whenever any adjustments are 

made or when tool is not in use.

LoADING THE TooL (FIG. 3)

 Keep the tool pointed away from yourself and others. Serious personal injury 

may result.

 Never load fasteners with the contact trip or trigger activated. Personal injury 

may result. 

 Disconnect tool from air supply before removing or re-installing no-mar pad.

1.  Read all 

safety Warnings

 before using tool.

2.  Connect to air supply. 
3.  Lock off trigger. (NS100B only)
4.  Push the magazine release (F) then slide magazine (E) to open chamber. 
5.  Position  stapler  on  a  stable  surface  so  contact  trip  is  pointing  upward  and  away  from 

you.

6.  Insert fasteners into the top chamber of the magazine.
7.  Slide magazine until it clicks, securing the magazine.

ACtUAtinG tOOl

 

To reduce the risk of injury, 

AlWAYs

 wear proper eye [ANSI Z87.1 (CAN/CSA 

Z94.3)] and hearing protection [ANSI S12.6 (S3.19)] when operating this tool.
The NS150B can be actuated using one of two modes: single sequential action trigger mode 

and bump action trigger mode. 
The NS100B can be actuated using the single sequential action trigger mode. 
Sequential action trigger - 

 (Fig. 1, 5)

 A fastener will fire each time the trigger is depressed as long as the contact trip 

remains depressed which could result in inadvertant actuation.

The sequential action trigger’s intended use is for intermittent fastening where very careful 

and accurate placement is desired. The NS100B is ready to use in the sequential action trig-

ger mode

On the NS150B, push selectable trigger button (A) from back of trigger and turn 

indicator to the 

 position. The tool is now ready to operate in the single sequential action 

trigger mode

to operate the stapler in sequential action mode:

1.  Depress the contact trip firmly against the work surface.
2.  Depress the trigger.
Bump action trigger - 

 (Fig. 1, 5)

The bump action trigger’s intended use is for rapid fastening on flat, stationary surfaces. 
Using  the  bump  action  trigger,  two  methods  are  available:

  place  actuation  and  bump 

actuation. On the NS150B, push selectable trigger button (A) from back of trigger and turn 

indicator to the 

 position. The tool is now ready to operate in the single sequential action 

trigger mode
To operate the tool using the 

plACe ACtUAtiOn method:

1.  Depress the contact trip against the work surface.
2.  Depress the trigger.
To operate the tool using the 

BUMp ACtUAtiOn method:

1.  Depress the trigger.
2.  Push the contact trip against the work surface. As long as the trigger is depressed, the tool 

will fire a fastener every time the contact trip is depressed. This allows the user to drive 

multiple fasteners in sequence.

 Do not keep trigger depressed when tool is not in use. Keep the lock-off switch 

rotated to the right (OFF) when the tool is not in use.

ADjUstinG Depth (fiG. 4)

 

to reduce risk of serious injury from accidental actuation when attempt

-

ing to adjust depth, AlWAYs:

•  Lock OFF trigger (NS100B only).
•  Disconnect air supply.
•  Avoid contact with trigger during adjustments.

The depth that the fastener is driven can be adjusted using the depth adjustment next to the 

trigger of the tool.
1.  To drive the fastener shallower, rotate the depth setting wheel (L) to the right.
2.  To drive a fastener deeper, rotate the depth setting wheel (L) to the left.

CLEARING A JAMMED FASTENER

Lock off trigger, disconnect air line from tool and remove fasteners from 

magazine before making adjustments or personal injury may result. 

 Keep the tool pointed away from yourself and others. Serious personal injury 

may result.
1.  Lock off trigger (NS100B only). 
2.  Disconnect air supply from tool.
3.  Push the magazine release then slide magazine to open chamber.
4.  Position  stapler  on  a  stable  surface  so  contact  trip  is  pointing  upward  and  away  from 

you.

5.  Remove ALL fasteners in the top chamber of the magazine.
6.  Remove bent fastener, using pliers if necessary.
7.  If driver blade is in the down position, insert screwdriver or other rod into nosepiece and 

push driver blade back in position.

8.  Reinsert fasteners into the top chamber of the magazine (see 

Loading the Tool).

9.  Slide magazine until it clicks, securing the magazine.
10.  Reattach air supply.

nOte: 

Should  fasteners  continue  to  jam  frequently  in  nosepiece,  have  tool  serviced  by  an 

authorized PORTER-CABLE service center.

COlD WeAtheR OpeRAtiOn

When operating tools at temperatures below freezing:
1.  Make sure compressor tanks have been properly drained prior to use.
2.  Keep tool as warm as possible prior to use.
3.  Make certain all fasteners have been removed from magazine.
4.  Lower air pressure to 80 psi or less.
5.  Reconnect air and and load nails into magazine. 
6.  Actuate the tool 5 or 6 times into scrap lumber to lubricate o-rings.
7.  Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal. 
8.  Always drain the compressor tanks at least once a daily.

hOt WeAtheR OpeRAtiOn

Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can 

deteriorate bumpers, o-rings and other rubber parts resulting in increased maintenance.

BELT HooK (FIG. 1)

The PORTER-CABLE nailers include an integrated belt hook (I) and can be rotated to either 

side of the tool to accommodate left or right handed users. It can also be rotated out of the 

way when not in use.

If the hook is not desired at all, it can be removed from the tool.

to remove belt hook:

1.  Lock off trigger.
2.  Disconnect the tool from air supply.
3.  Using the appropriate hex wrench, remove the end cap screws from the end cap of the 

tool.

4.  Remove the belt hook.
5.  Replace end cap and gasket. Ensure that the three screws are tight.
6.  Replace and tighten air fitting.

MAINTENANCE

 

Lock off trigger, disconnect air line from tool and remove fasteners from 

magazine before making adjustments or personal injury may result.

DAILy MAINTENANCE CHART

ACTIoN

WhY

hOW

Drain compressor tanks 

and hoses daily.

Prevents accumulation 

of moisture in com-

pressor and nailer.

Open petcocks or other 

drain valves on compressor 

tanks. Allow any accumulated 

water to drain from hoses.

Clean magazine, magazine 

release and contact 

trip mechanism.

Permits smooth opera-

tion of magazine, reduces 

wear and prevents jams. 

Blow clean with compressor 

air. The use of oils, lubricants 

periodically or solvents is 

not recommended as they 

tend to attract debris.

Before each use, check 

to insure all screws, 

nuts and fasteners are 

tight and undamaged. 

Prevents jams, leaks 

and premature fail-

ure of tool parts.

Tighten loose screws 

or other fasteners using 

the appropriate hex 

wrench or screwdriver. 

CLEANING

  Never  use  solvents  or  other  harsh  chemicals  for  cleaning  the  non-metallic 

parts of the tool. These chemicals may weaken the materials used in these parts. Use a cloth 

dampened only with water and mild soap. Never let any liquid get inside the tool; never immerse 

any part of the tool into a liquid.

REpAIRS

For assistance with your tool, visit our website at www.deltaportercable.com for a list of service 

centers, or call the PORTER-CABLE Customer Care Center at (888) 848-5175. 

SERvICE 

REpLACEMENT pARTS
Use only identical replacement parts. For a parts list or to order parts, visit our website at ser-

vicenet.porter-cable.com. You can also order parts from your nearest PORTER-CABLE Factory 

Service Center or PORTER-CABLE Authorized Warranty Service Center. Or, you can call our 

Customer Care Center at (888) 848-5175. 
SERvICE AND REpAIRS
All quality tools will eventually require servicing and/or replacement of parts. For information 

about PORTER-CABLE, its factory service centers or authorized warranty service centers, visit 

our website at www.deltaportercable.com or call our Customer Care Center at (888) 848-5175. 

All  repairs  made  by  our  service  centers  are  fully  guaranteed  against  defective  material  and 

workmanship. We cannot guarantee repairs made or attempted by others.
You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson, 

Tennessee 38305 - Attention: Product Service. Be sure to include all of the information shown 

on the nameplate of your tool (model number, type, serial number, etc.).

ACCESSoRIES

  Since  accessories  other  than  those  offered  by  Porter-Cable  have  not  been 

tested with this product, use of such accessories could be hazardous. For safest operation, 

only Porter-Cable recommended accessories should be used with this product.
A complete line of accessories is available from your PORTER-CABLE Factory Service Center 

or a PORTER-CABLE Authorized Warranty Service Center. Please visit our Web Site www.del-

taportercable.com for a catalog or for the name of your nearest supplier.

thRee YeAR liMiteD WARRAntY

PORTER-CABLE will repair, without charge, any defects due to faulty materials or workman-

ship for three years from the date of purchase. This warranty does not cover part failure due to 

normal wear or tool abuse. For further detail of warranty coverage and warranty repair informa-

tion,  visit  www.deltaportercable.com  or  call  (888)  848-5175.  This  warranty  does  not  apply  to 

accessories or damage caused where repairs have been made or attempted by others. This 

warranty gives you specific legal rights and you may have other rights which vary in certain 

states or provinces.
In addition to the warranty, PORTER-CABLE tools are covered by our:

1  YeAR  fRee  seRviCe: 

PORTER-CABLE  will  maintain  the  tool  and  replace  worn  parts 

caused by normal use, for free, any time during the first year after purchase.

90 DAY MOneY BACK GUARAntee: 

If you are not completely satisfied with the performance 

of your PORTER-CABLE Power Tool, Laser, or Nailer for any reason, you can return it within 90 

days from the date of purchase with a receipt for a full refund – no questions asked.

lAtin AMeRiCA: 

This warranty does not apply to products sold in Latin America. For products 

sold in Latin America, see country specific warranty information contained in the packaging, call 

the local company or see website for warranty information.
To register your tool for warranty service visit our website at www.deltaportercable.com.

WARninG lABel ReplACeMent

If  your  warning  labels  (Fig.  6)  become  illegible  or  are  missing,  call  (888)  848-5175  for  a  free 

replacement.

Fig. 3

Fig. 5

F

E

NS150B

NS150B

Fig. 2

NS100B

NS100B

M

N

o

fig. 4

L

Summary of Contents for NS100B

Page 1: ...eur effectuer un ent retien ou d bloquer des attaches coinc es alors que l outil est raccord la source d alimentation La herramienta en funcionamiento puede generar residuos vol tiles materiales cola...

Page 2: ...uteur comme sur un toit Ne pas enfoncer d attaches pr s du bord de la pi ce La pi ce risque de se fendre faire ricocher l attache et blesser l op rateur ou un coll gue de travail Il est possible que l...

Page 3: ...rotate the depth setting wheel L to the right 2 To drive a fastener deeper rotate the depth setting wheel L to the left Clearing a Jammed Fastener Lock off trigger disconnect air line from tool and re...

Page 4: ...pr t fonctionner en mode de d tente action s quentielle Pour le mod le NS150B ramener le bouton de la d tente s lecteur A de l arri re de celle ci et mettre l indicateur la position L outil est mainte...

Page 5: ...cte la l nea de aire de la herramienta y extraiga los clavos de la fuente antes de efectuar ajustes caso contrario podr a pro ducirse una lesi n La engrapadora NS100B est equipada con un interruptor d...

Page 6: ...s Le compresseur peut actionner tout outil quel que soit le taux de production El compresor ser suficiente para las herramientas a todo ndice de producci n Compressor will be sufficient at slow or mod...

Page 7: ...air restreinte V rifier l alimentation pneumatique et les raccords Vis de l embout desserr es Serrer les vis de l embout l aide d une cl hexagonale appropri e Attaches de dimension angle inappropri s...

Reviews:

Related manuals for NS100B