7

Employer must enforce compliance with the safety warnings

and all other instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.

For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.

FOREWORD

Porter-Cable Model COIL350 is a heavy duty pneumatic framing nailer. It is
designed to install .099 to .131 diameter, full round flat head wire collated,
coil framing nails of various lengths (1

1

/

2

" to 3

1

/

2

" long). Fastener collation

angle is 15°.

Use approved Porter-Cable fasteners only.

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 70 and 120 PSI (Pounds per Square Inch)(4.8 to 8.3 BAR).
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is
ideal.

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil
into the tool’s air inlet at the beginning of each workday.

The tool is equipped with a 

1

/

4

" male “quick connector”. A 

3

/

8

" male “quick

connector” is available from Porter-Cable and may be used in situations where

1

/

4

" supply line is not available. A 

3

/

8

" supply line (and fittings) are required for

maximum tool performance. The tool must always be connected to the air
supply with a coupling such that all pressure is removed from the tool when the
coupling is disconnected.

All air line components (hoses, connectors, filters, regulators,

etc.) must have a minimum working pressure rating of at least 150 PSI
(10.3 BAR) or 150% of maximum system potential, whichever is greater.

Do not connect tool to pressure which potentially exceeds 200 PSI

(13.7 BAR).

Only connect tool to air supply hose with a coupling that

automatically removes all pressure from the tool when the coupling
is disconnected.

Disconnect tool from air supply before performing maintenance,

clearing a jammed fastener, leaving work area, moving tool to
another location, or handing the tool to another person.

PREPARING THE TOOL

1. After reading and understanding this entire manual, connect tool to 
air supply (Fig. 18).

Never point tool at yourself or others.

EMPLOYER’S RESPONSIBILITIES

FUNCTIONAL DESCRIPTION

908987 - 12-20-02.qxd  12/17/02  10:07 AM  Page 7

Summary of Contents for COIL350

Page 1: ...___________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions befo...

Page 2: ...in conformity with the regulations EN292 2 section 3 of 1992 EN292 1 section 5 of 1992 EN1050 1993 EN792 13 2000 E ESPANOL DECLARACION DE CONFORMIDAD CE Declaramos bajo nuestra sola responsabilidad q...

Page 3: ...ttention to these sections SAFETY GUIDELINES DEFINITIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS There are certain applications for which this tool was d...

Page 4: ...t Check manual for triggering options See Using the Tool with Selectable Triggering Options section of this manual 5 Never point tool at yourself or others in work area Fig 3 6 Never use oxygen or oth...

Page 5: ...operable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and safety mechanism Fig 8 15 Do not use tool without safety warning la...

Page 6: ...ve fasteners on top of other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 26 Do not drive fasteners close to the edge of the workpiece The...

Page 7: ...the life of the tool If an in line oiler is not available place five or six drops of Porter Cable Air Tool Oil into the tool s air inlet at the beginning of each workday The tool is equipped with a 1...

Page 8: ...in Fig 19 and depress latch B Fig 19A Open feeder cover and allow magazine nail holder to swing open see Fig 20 3 Adjust nail support C Fig 20 for desired nail length The nail support can be lifted a...

Page 9: ...er to fire a fastener Allow tool to recoil away from work surface as fastener is driven This single sequential actuation method provides the most accurate fastener placement OR 2 To use the tool in th...

Page 10: ...is leaking air or needs any other repair The depth to which a fastener is driven is controlled by the depth adjustment A Fig 26 The depth of drive is factory adjusted to a maximum setting Test fire a...

Page 11: ...instructions in PREPARING THE TOOL to reload fasteners CLEAN AND INSPECT DAILY Disconnect tool from air supply before cleaning and inspection Correct all problems before placing the tool back in use...

Page 12: ...performing any Service Procedure SYMPTOM PROBLEMS SOLUTIONS 1 Air leak near top of Loose screws Tighten screws tool or in trigger area Worn or damaged Install Overhaul Kit o rings or seals 2 Tool doe...

Page 13: ...eb Site www porter cable com for a catalog or for the name of your nearest supplier Since accessories other than those offered by Porter Cable Delta have not been tested with this product use of such...

Page 14: ...than our Service Centers or Authorized Service Stations ANY IMPLIED WARRANTY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WILL LAST ONLY FOR ONE 1 YEAR FRO...

Page 15: ...r obtenir de l aide pour en rep rer un Pour obtenir des pi ces et accessoires pour les produits Porter Cable Delta s adresser tout distributeur Porter Cable Delta centre de service agr ou centre de se...