background image

14- ENG 

A07708

1.   Obtain a funnel

, six ounces 

of *RV antifreeze, and 16 - 36 

inches of garden hose with a 

male hose connector attached to 

one end.

Use only RV 

antifreeze. Any 

other antifreeze is corrosive and 

can damage pump.
2.

  Disconnect spark plug wire.

3. 

  Connect length of garden hose to 

water inlet of pump.

4.

  Add *RV antifreeze to hose as 

shown.

STORAGE

ENGINE

Consult the Engine Owners Manual for 

the manufacturer's recommendations 

for storage.

5. 

  Pull engine starter rope slowly 

several times until antifreeze 

comes out of high pressure hose 

connection of pump.

6. 

  Remove garden hose from water 

inlet of pump.

7. 

  Reconnect spark plug wire.

*Windshield washer fluid may also be
used

PRESSURE WASHER

1. 

  Drain all water from high 

pressure hose, coil it, and  store 

it in cradle of the pressure 

washer handle.

2.

  Drain all water from spray gun 

and wand by holding spray 

gun in a vertical position with 

nozzle end pointing down and 

squeezing trigger. Store in gun 

holder.

3.

  Store chemical hose so it is 

protected from damage.

4. 

  If space is needed, remove 

handles and replace as shown.

PUMP

The manufacturer recommends using 

a pump protector/winterizer when 

storing the unit for more than 30 days 

and/or when freezing temperatures 

are expected. If a pump protector/

winterizer is not available, *RV 

antifreeze needs to be run through the 

pump as outlined in the steps below.
NOTE: Using a pump protector/

winterizer or *RV antifreeze is to 

provide proper lubrication to the 

internal seals of the pump regardless 

of temperature or environment.

Summary of Contents for A07708-0412-0

Page 1: ...No A07708 0412 0 ESPA OL P GINA 19 FRAN AIS PAGE 37 To learn more about Porter Cable visit our website at http www porter cable com PCH2800C Copyright 2004 Porter Cable Corporation The Model and Seria...

Page 2: ...other similar items then an approved spark arrester must be installed and is legally required in the state of California It is a violation of California statutes section 130050 and or sections 4442 an...

Page 3: ...a location occupied by humans or animals Some cleaning fluids contain substances which could cause injury to skin eyes or lungs Use only cleaning uids speci cally recom mended for high pressure washe...

Page 4: ...re washers Wear protective clothing to protect eyes and skin from contact with sprayed materials Use of acids toxic or corrosive chemicals poisons insecticides or any kind of ammable solvent with this...

Page 5: ...HOW TO PREVENT IT Unsafe operation of your pressure washer could lead to serious injury or death to you or others Do not use chlorine bleach or any other corrosive compound Become familiar with the o...

Page 6: ...dle assembly and push each nozzle holder into place 5 Remove ve colored quick connect nozzles from plastic bag and insert them into correct grommet on the nozzle holder NOTE Nozzles are color coded to...

Page 7: ...e pump to mix with the water See How To Apply Chemicals Cleaning Solvents instructions in this section Compare the illustrations with your unit to familiarize yourself with the location of various con...

Page 8: ...xes cleaners or cleaning solvents with the water to improve cleaning effectiveness Water Supply All pressure washers must have a source of water The minimum requirements for a water supply are 20 PSI...

Page 9: ...h enough to penetrate human and animal esh which could result in amputation or other serious injury Leaks caused by loose ttings or worn or damaged hoses can result in injection injuries DO NOT TREAT...

Page 10: ...through chemical injection system to rinse system thoroughly If chemicals remain in the pump it could be damaged Pumps damaged due to chemicals will not be covered under warranty NOTE Chemicals and s...

Page 11: ...er on spray gun to relieve any water pressure in hose or spray gun 5 See Storage section in this manual for proper storage procedures STARTING Prior to starting refer to your engine manual for proper...

Page 12: ...hecks will be required ENGINE Consult the Engine Owners Manual for the manufacturer s recommendations for any and all maintenance NOTE The frame is equipped with an oil drain hole to help make changin...

Page 13: ...ith clean water 5 Direct water supply into spray wand to back ush loosened particles for 30 seconds 6 Reassemble the nozzle to the wand 7 Reconnect spray wand to gun and turn on water supply 8 Start p...

Page 14: ...y also be used PRESSURE WASHER 1 Drain all water from high pressure hose coil it and store it in cradle of the pressure washer handle 2 Drain all water from spray gun and wand by holding spray gun in...

Page 15: ...ter source from the pump inlet and turn the water source on to remove all air from the hose When there is a steady stream of water present turn water source off Re connect water source to pump inlet a...

Page 16: ...oose hose connection Loose connections Tighten Piston packings worn Have replaced by AWSC Worn or broken o rings Have replaced by AWSC Pump head or tubes damaged from freezing Have replaced by AWSC Wi...

Page 17: ...17 ENG A07708 NOTES...

Page 18: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...