9 - ENG
1. Read all
Safety Warnings before using tool.
2. Connect the air supply to the tool.
3. Insert fasteners (L) into T-slot (K) on end cap of magazine (J) past the nail stop (E).
nOTe: Magazine will hold two full fastener strips.
4. Pull
pusher (I) back until the nail stop (E) falls behind the fasteners.
nOTe: Do not allow the pusher to snap
forward against the nail strip, allowing this
to happen could damage the nail collation.
nOTe: This tool has a low nail lock out
device which will not allow the tool to drive
fasteners when the fastener quantity in the
magazine is reduced to four. When unload-
ing and loading the magazine always make
sure these four nails have been removed
from the magazine. If the nails are not
removed from the magazine and the tool is
reloaded and actuated, the nails will cause
the tool to jam.
ACTUATInG TOOl
To reduce the risk of injury,
AlWAyS wear proper eye ANSI Z87.1
(CAN/CSA Z94.3) and hearing protection ANSI S12.6 (S3.19) when operating this tool.
The tool can be actuated using one of two modes: single sequential actuation trigger
mode and contact actuation trigger mode.
Single Sequential actuation trigger -
(Fig. 5)
Allow the tool to recoil off the work
surface after actuation. If the contact trip remains
depressed a nail will be driven each time the trigger is
released and pulled, which could result in accidental
actuation, possibly causing injury.
The sequential actuation trigger’s intended use is
for intermittent fastening where accurate fastener
placement is desired.
To operate the tool in Single sequential actuation
mode:
1. Depress the contact trip firmly against the work
surface.
Fig. 5
S
Trigger lock button
Trigger mode selector button
Fig. 4
I
l
Fig. 2
D
J
K
l
Fig. 3
l
e