Porter & Charles CG60WOK-F Operating And Installation Instructions Download Page 4

Installation and connection

When using your gas appliance
follow basic safety precautions
including the following:

~

Read all instructions before using for

the first time.

~

Be certain your appliance is

properly installed and grounded by a
qualified technician.

~

To guarantee the electrical safety of

this appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician.

~

Install the appliance so that the

power cord and gas piping do not
come into contact with any portion of
the cooktop which may become hot
during use.

~

 

Do

 

not

 

connect

 

the

 

appliance

 

to

 

the

 

main

 

electrical

 

supply

 

using

 

an

extension

 

cord.

 

Extension

 

cords

 

do

 

not

meet

 

the

 

safety

 

requirements

 

of

 

this

appliance.

~

Before servicing, turn off the gas

valve and disconnect the power supply
by either removing the fuse, unplugging
the unit or manually “tripping” the
circuit breaker.

~

 

This

 

equipment

 

has

 

not

 

been

 

designed

 

for

 

maritime

 

use

 

or

 

for

 

use

 

in

mobile

 

installations

 

such

 

as

 

aircraft

 

or

recreational

 

vehicles.

 

However,

 

under

certain

 

circumstances

 

it

 

may

 

be

possible

 

for

 

installation

 

in

 

these

applications.

 

Please

 

contact

 

the

Technical

 

Service

 

Department

 

with

specific

 

requirements.

~

After connecting the appliance test

for leaks according to the installation
instructions.

~

 

If

 

there

 

is

 

any

 

doubt

 

concerning

 

installation

 

contact

  

Technical

Service

 

Department.

IMPORTANT SAFETY INSTRUCTIONS

4

 di 3

1

        WARNING:

The  appliance  must  be  isolated  from  the  gas  supply  piping 

system by closing its individual manual shut-off valve during any pressure testing 

of  the  gas  supply  piping  system  at  test  pressures  equal  to  or  less  than  1/2  psi 

(3.5 kPa). the maximum gas supply pressure in accordance with the inlet pressure 

rating of the gas appliance pressure regulator supplied. 

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory, or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the appliance. 

During use the appliance becomes hot. Care should be taken to avoid touching heating 

elements inside the oven. 

WARNING:

Summary of Contents for CG60WOK-F

Page 1: ...nstallation Instructions Gas Cooktop Model CG60WOK F CG76WOK F CG90WOK F To prevent accidents and machine damage read the Operating Manual before installation or use e n CURRENT STANDARD ANSI Z21 1 20...

Page 2: ...o the installer Please leave this instruction book with the consumer for the local electrical gas inspector s use 2 di 31 Leak testing of the appliance shall be conducted according to the manufacturer...

Page 3: ...easurement section of this manual A licensed electrician with relevant qualifications must perform electrical work when installing or servicing the appliance The supply cable and fuse rating must be s...

Page 4: ...nstallations such as aircraft or recreational vehicles However under certain circumstances it may be possible for installation in these applications Please contact the Technical Service Department wit...

Page 5: ...a pan Do not use pans that extend past the burner grate Using larger pans may cause the flames to spread out and damage the surrounding countertop or other countertop appliances For safety and stabili...

Page 6: ...ot in use Do not let cooking grease or other flammable materials accumulate on the appliance Do not leave the cooktop unattended while in use Boil overs cause smoking and greasy spill overs may ignite...

Page 7: ...Under no circumstance open the outer casing of the appliance While the appliance is under warranty repairs should only be performed by a Miele authorized service technician Otherwise the warranty is v...

Page 8: ...eassemble the parts in the proper order see Cleaning and care Wipe the cooktop with a damp cloth and dry thoroughly Metal components have a protective coating which may give off a slight odor the firs...

Page 9: ...turn the corresponding control knob counterclockwise to the largest flame symbol Release the knob The ignitor will click and ignite the gas The ignition process lasts about 2 5 seconds The flame shou...

Page 10: ...with a smaller diameter than the pan support and pots that do not sit securely without wobbling are hazardous and should not be used Suitable pans Unlike pans used on an electric cooktop the bases do...

Page 11: ...p Mini Trivet Examples of positioning of mini trivet MODEL CG60WOK F 11 di 30 MODEL CG90WOK F MODEL CG76WOK F The mini trivet included with this cooktop is to be used for cooking vessels of diameter 1...

Page 12: ...tes cooktop and knobs with a sponge and a mild solution of warm water and liquid dish soap Soak baked or hardened spills Dry the cooktop and grates thoroughly after cleaning The stainless steel surfac...

Page 13: ...e holes are clean and completely dry Wipe the burner base clean with a damp cloth and then dry Gently wipe the ignitor and ignition safety control with a slightly damp cloth and then wipe dry Make sur...

Page 14: ...he burners See Cleaning and Care Dry the igniters Plug the cooktop in and restore power If lack of power is the problem the cooktop can be lit with a match See Using the cooktop during a power failure...

Page 15: ...Department at the address on the back of this booklet When contacting Technical Service please quote the serial number and model of the cooktop This information is visible on the silver data plate su...

Page 16: ...Installation Instructions To prevent accidents and machine damage read these instructions before installation or use 15 di 36...

Page 17: ...uld only be installed as shown in the illustrations while maintaining the required safety distances shown Do not install the cooktop between two tall cabinets this is a fire hazard a indicates cooktop...

Page 18: ...e and the regulator must be easily accessible to the consumer after the appliance is installed This appliance must be disconnected from the gas supply during any pressure testing of the system perform...

Page 19: ...s measured from cooking surface top of cooktop grate 2 If installing with an overhead range hood check the hood specification for minimum required clearances 3 This specification does not apply for ca...

Page 20: ...pth of cooktop casing from benchtop surface 2 7 Gas Connection Electrical Supply Cord 24 2 7 35 20 2 4 1 2 8 3 MODEL CG90WOK F Depth of cooktop casing from benchtop surface 2 7 NG Universal LPG 11500...

Page 21: ...10 di 30 Appliance dimensions MODEL CG60WOK F MODEL CG76WOK F...

Page 22: ...own in the diagram Seal the cut surfaces with a suitable heat resistant sealant to avoid swelling caused by moisture If during installation the corners of the frame are not flush with the work top sur...

Page 23: ...Gas Connection Gas pressure regulator Feed the power cord through the cut out to the power outlet Set the cooktop in the cut out and center it Install the appliance so that the power cord and gas pipi...

Page 24: ...sufficient seal for the worktop Do not let sealant get in between the cooktop frame and the worktop This could cause difficulties if the cooktop ever needs to be taken out for servicing and possibly...

Page 25: ...ance is equipped with a 3 3 f t 1 0 m long power cord that is ready for connection to the appropriate outlet Place the power outlet so that it is accessible after the appliance has been installed in t...

Page 26: ...controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Electrical connection MODEL CG76WOK F CG90WOK F IGNITION GENERATOR TRIPOLAR TERMINAL MICRO UN...

Page 27: ...gas supply line by closing its individual manual shut off valve at test pressures equal to or less than psi 3 5 kPa Any pipe connections must be made using a thread sealant approved for gas connection...

Page 28: ...s steel gas hose accordion type may be used between the gas connection and the regulator This will allow the appliance to be lifted out of the countertop for cleaning or servicing Make sure that any d...

Page 29: ...0mm GAS Injector Diameter 1 100 mm N ormal Pressure in w c N ormal Pressure mbar Burners N DESCRIPTION 2 RAPID 3 AUXILIARY 4 WOK 1 SEMI RAPID 10 11 0 4 0 11 0 4 0 11 0 4 0 LP 11 0 NG 4 0 85 35 8 250 1...

Page 30: ...s The flame should always stay alight when the burner is switched on even if there is an abrupt shift from the maximum to minimum flame position If the flame does not stay alight adjust it as follows...

Page 31: ...liance Old appliances contain materials that can be recycled Please contact your local recycling center about the possibility of recycling these materials Before discarding an old appliance disconnect...

Page 32: ...k up Please attach your invoice to this manual for easy future reference To register your purchase you can either complete the section below to mail or fax or register online at www porterandcharles c...

Page 33: ...COD 208623 03 18 04 2018...

Reviews: