CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The cooker should be connected according to local regulations,
using either a rigid or flexible connections.
a) For building in: Use a continuous flexible stainless steel pipe, as
per current installation standards, which can be extended to a
maximum of 2000 mm.; the ends of the pipe must be fitted with
an ISO 228/1coupling and gasket or an ISO 7/1 threaded
coupling with mechanical gasket.
b) For free standing: A non-metallic flexible pipe can be used
as long as it complies with current standards and the
following installation instructions are observed: the pipe
must be longer than 400 mm and shorter than 1500 mm; it
must not exceed 50°C in any point; it is not pulled or
twisted; it cannot be choked and the entire edges, sharp
corners or other similar hazards.
Before connecting the non-metallic flexible pipe, the brass adapter and gasket supplied with
the cooker and/or available form the reseller must be fitted to the pipe/gas train on
the back of the cooker. The regulator provided should be positioned between the brass
adapter and the non metallic flexible pipe.
c) A certified gas plumber must complete the installation and meet with local regulation
requirements for gas connections. Where the unit has an armour cable a certified electricain
must complete the electrical connection. The white, or neutral wire will not be used and must
be capped using a marrette.
d)
Measurements
Please note that all dimensions provided are in millimeters (mm.) The sizes allow for only a small
degree of error so all cut-outs must be precise and square
Cooker Measurements
92
5
m
m
640
m
m
76
2 m
m
640
m
m
92
5
mm
76
2 m
m