For Air Baths:
1. Never handle the bath by the blower, piping or other equipment.
2. Make sure the manifold and airlines are protected when moving the tub into the house.
3. An access panel measuring 16" x 14" (406 x 356mm) must be provided for the blower for any future servicing.
4. The blower must not be insulated and must have sufficient air space to permit proper operation. Surrounding ambient air
temperature should be between 72°F and 86°F.
5. The heating element on your blower heats the air blown into the tub to prevent the water from cooling too quickly. It will
not, under any circumstances, reheat or maintain the temperature of bath water.
6. The area underneath and around the tub must be cleaned thoroughly before finalizing installation to prevent any particles
from entering the blower or being blown into the air jets.
7. Before filling the tub, clean installation debris and dirt from the interior of the tub. If necessary, use the soft brush
attachment of a vacuum cleaner.
8. Fill tub and test for proper operation and leaks. Note: The blower must be plugged into a GFCI protected outlet.
9. The drain supplied must be used. It is part of the Air Bath and the system will not function correctly without it.
List of Required Tools and Supplies
Tools
Supplies
Optional Components (not included):
• Level
• Nails
• Tile Bead Kits (P/N 751755-100)
• Tape Measure
• Putty
• Pipe Wrench
• Caulking (waterproof)
Required Components:
• Slip Joint Pliers
• 1 X 4 Stringers
• Drain (included)
• Screw Driver
• Drop Cloth
• Bath Filler (not included)
• Standard Woodworking Tools
• Cement, Plaster, Grout
• Personal Safety Equipment
• Liquid Nails (Freestanding Modes Only)
• Caulking Gun
DECK TO C/L OVERFLOW
SPECIFICATIONS
TABLE 1
GENERAL SPECIFICATIONS AIR BATHS -
DROP IN AND RECESS MODELS
Fore more details, see specification page per model at www.porcher-us.com
*note - on Air Baths the drain included with the tub must be used. The drain outlet is directly under the drain hole in the tub.
2-1/2"
64mm
50 lbs./ft
2
40 lbs./ft
2
48 lbs./ft
2
54 lbs./ft
2
Gallon to
Overflow
Product
Weight
Weight with
Water / Floor
Loading
Rough-In
Recess
A x C
Cut Out
Pier
G x F
Drain /
Overflow
Description
Tetsu
™
5-1/2' x 32"
(140 x 813mm)
60525
Tetsu
™
5-1/2' x 36"
(140 x 914mm)
60545
Lutezia
™
5-1/2' x 36"
(140 x 914mm)
60645
Archive
™
Oval
5-1/2' x 36"
(140 x 914mm)
60745
X 17" (432mm)
Y 10-1/8" (257mm)
Z 7-1/8" (181mm)
X 17-1/4" (438mm)
Y 10" (254mm)
Z 5-1/4" (133mm)
X 17-3/8" (441mm)
Y 10" (254mm)
Z 7" (178mm)
X 17-3/8" (441mm)
Y 9-1/2" (241mm)
Z 6-3/8" (62mm)
64-1/2" x 30-1/2"
(1638 x 775mm)
64-1/2" x 34-1/2"
(1638 x 880mm)
64-1/4" x 34-1/2"
(1630 x 880mm)
Use Template
Provided
66" x 32"
(1677 x 813mm)
66-1/4" x 36-1/4"
(1682 x 920mm)
66" x 36"
(1677 x 914mm)
See Template
Dimensions
-Next Page-
85 lbs.
(39 kg.)
85 lbs.
(39 kg.)
85 lbs.
(39 kg.)
121 lbs.
(55 kg.)
78 gal.
(295 l.)
68 gal.
(260 l.)
84 gal.
(320 l.)
80 gal.
(300 l.)