754550-100 Rev. B
15
AIR BATH DRAIN INSTALLATION - ALL AIR BATHS
NOTE:
All Porcher Air Bath configurations include a drain. Other drains cannot be used.
NOTE:
Include a 9" (229mm) wide by 18" (457mm) long cut-out in floor for drain.
DRAIN CONNECTION AND
SYSTEM TEST
(before installing bath)
With supplied cable drain assembled to
bath, connect drain outlet to waste line in
accordance with the drain assembly
instructions. Tighten all drain joints
securely. Check the couplings and make
sure they are hand-tight. Clean the air bath
and fill with water to a point 2" (51mm) below
the overflow. Recheck the couplings and
make certain that they are not leaking.
(Although the couplings are factory
tightened and inspected, some loosening
may have occurred during transit.) Make
sure the air bath is connected to the
electrical supply and turn the air bath on.
Check for leaks around all piping
connections while the air bath is running.
DRAIN STOPPER
WITH
ADJUSTABLE
BOLT
METAL STRAINER
BOLT
DRAIN WASTE
FLANGE
METAL
STRAINER
FLAT RUBBER
GASKET
PLASTIC DRAIN BASE
OVERFLOW
ESCUTCHEON
OVERFLOW
ASSEMBLY
WEDGE
GASKET
SET
SCREW
DRAIN ACTUATOR SHAFT
OVERFLOW
RETAINER
OVERFLOW
ASSEMBLY
VERTICAL
FLEX PIPE
CLOSE
OPEN
OVERFLOW NUT WITH O-RING
AIR BATH NUT
WITH WASHER
AND GASKET
HORIZONTAL
DRAIN PIPE
PLASTIC
DRAIN BASE
90° ELBOW
AIR BATH DRAIN ILLUSTRATION