EMERGENCY STOP
SECTION FOUR
| OPERATING INSTRUCTIONS
An emergency stop button is provided on the control pendant. Once
depressed, this isolates power to the raise and lower functions.
To restore functionality, twist the emergency stop button clockwise to
release the button, as shown below.
Turning the Maintenance Isolator switch to the ‘0’ position also has the
effect of isolating power to the raise and lower functions.
BATTERY CHARGING
A battery condition meter is fitted to the POP-UP PUSH 6 ECO as shown. To
check the battery condition, elevate the platform from ground level whilst at
the same time pressing the red button above the battery condition meter.
This is the only way to obtain an accurate reading. The battery will require
charging if there is less than 4 bars on the display. Do not attempt to use the
machine in this state as battery damage may occur. Never allow the battery
to run completely flat as this damages the cells and can lead to premature
battery failure. It is good practice to charge the battery daily to ensure
optimum battery condition. The POP-UP PUSH 6 ECO is supplied with a built-
in multi voltage automatic battery charger, for supply voltages between 90V
and 240V AC. The battery charger is located on the underside of the platform.
TO CHARGE THE BATTERY, FOLLOW THESE STEPS:
1
Turn the Maintenance Isolator switch to ‘0’ (OFF) position.
2
Connect the battery charger lead to the POP-UP PUSH 6 ECO at the
point shown.
3
Connect the battery charger to the power supply (either 110V or
240V AC at 50 Hz depending on the mains supply).
4
Turn the Maintenance Isolator switch to ‘2’ (CHARGE) position.
5
The battery should be fully recharged once the 95% LED is
illuminated on the charging indicator.
Page 12 of 23
POP-UP PUSH 6 ECO OPERATOR’S SAFETY AND MAINTENANCE HANDBOOK (v.0.4.0409)
EMERGENCY LOWERING
To lower the platform in the event of an emergency, a control is provided
at the chassis.
Turning the knob in an ANTICLOCKWISE direction, as shown, opens the
lift valve. Once the valve is fully open the platform will lower, at this point
please stand back to ensure your safety. Always close the valve after use.