3
1. MANUAL OVERVIEW
Follow the instruction manual for hydro-massage systems closely to ensure the best use of massage capabilities and to
avoid problems or failure caused by inappropriate operation.
We recommend hiring a quali
fi
ed ROCA POOL-SPA installer to install the bathtub.
The system to which the bathtub is connected must be equipped with a residual current device. Only a person with
appropriate electrical quali
fi
cations is permitted to connect the bathtub to the electrical system. This person should
con
fi
rm correct bathtub connection in the Warranty Card. This is required in order for the warranty to be deemed valid
by the manufacturer!
2. WATER MASSAGE
Water massage is generated by a water pump located under the bathtub. The water pump power is 900 W.
Water massage is performed by nozzles installed in the bathtub. Water is forced by the pump through the nozzles
located inside the bathtub. The intensity of water massage can be controlled by adding air to the water stream
fl
owing
out of the nozzles (aeration). The more air, the more intense the stream.
3. AIR MASSAGE (Pearl bath)
Air massage (so-called “pearl massage”) can be used as an addition to hydro-massage. It involves using small air bubbles
to perform a gentle relaxing massage.
The air massage is generated by an air blower. The blower power is 500 W. Small bubbles of air are forced into the bathtub
through a system of tubes and nozzles under the bathtub.
4. DISINFECTION
The water system of hydro-massage bathtubs requires periodic disinfection. Perform it regularly to ensure clean and
pleasant bathing.
Disinfecting the water and air system:
Every 2 to 4 weeks – depending on the frequency of bathtub use –
fi
ll the bathtub with clean cold water above the nozzle
level and add 50 ml of a disinfecting liquid for each 100 l of water in the bathtub. Activate the pump and the blower for
a few minutes. Leave the bathtub
fi
lled for 10-20 minutes, and then activate the device for a few minutes again. Then,
empty the bathtub and rinse it thoroughly with clean tepid water.
Disinfecting the air system (temporarily):
Fill the bathtub with clean cold water up to a level of ca. 5-6 cm and add ca. 20 ml of disinfectant. Activate the blower
for 1 minute, and then leave the bathtub
fi
lled for 10 minutes. Repeat this step two more times. Then, empty the bathtub
and rinse it thoroughly with clean tepid water. Approximately 10 minutes after draining the water, activate air massage
(blower) for ca. 1 minute to dry the air nozzles completely.
5. TRANSPORT
The bathtub should be transported in its original container. When moving the bathtub, hold it by its aluminum frame or
acrylic parts.
Never use the tubes and hoses of massage systems as handles.
6. PREPARING THE ROOM
When preparing the room for bathtub installation, make sure it meets the following requirements:
- appropriate size
- 230 V~ power supply
- water inlet and outlet
- leveled surface
- appropriate ventilation
- for corner bathtubs: the corner where the bathtub will be installed should have a right angle, and the vertical deviation
of walls should not exceed 1 mm/m.
7. PRELIMINARY BATHTUB PLACEMENT
After unpacking the bathtub, install the enclosed legs immediately (placing the bathtub without its legs may damage the
over
fl
ow). The package included with the bathtub contains parts of these legs.