Pool Technologie ELLY20NPSB-G0HX16 Instructions For Use Manual Download Page 10

2.

 

ELECTRONICS UNIT 

2.1. Interface

ELEMENT 

STATUS 

MEANING 

Red LED 

Continuously on 

Electronics unit powered off 

Flashing 

Alarm activated 

Green LED 

Continuously on 

Production in progress 

Screen 

Default display 

Production setpoint 

Flashing display 

Information awaiting validation, or alarm 

Frozen display 

Confirmed information 

2.2.

 

Switching on 

 

When connecting the electronics unit to a power supply :  

After about a minute, production starts automatically, according to the setpoint displayed on the screen. 

 

If the electronics unit is powered off (screen off, red LED on) : 

Press at least twice on the upper control key. After about a minute, production starts automatically, according to 

the setpoint displayed on the screen. 

2.3.

 

Switching off 

Set the production setpoint to 

00

 using the top key 

(no confirmation required) 

:  after a few seconds, the screen turns 

off and the red LED comes on. 

The internal ventilator of the electronics unit can may be able to continue running as long as the unit is powered on. 

2.4.

 

Adjustment of the inversion frequency of the current supplying the cell 

(optional)

 

I

Reversing the flow aims to prevent scale deposits on the cell. The frequency at which flow is reversed must be 

correctly set following the table below in order to ensure that the cell continues to operate correctly in the long term. 

 

Possible settings :  02

04

06

08

10

12

14

16 

(hours)

.

 

 

Default setting :  04

.

 

Water hardness (°f) 

0 to 2 

2 to 5 

5 to 8 

8 to 12 

12 to 20 

20 to 40 

40 to 60 

> 60 

Water hardness (mg/L) 

0 to 20 

20 to 50 

50 to 80  80 to 120  120 to 200  200 to 400  400 to 600 

> 600 

Reversal frequency (h) 

16 

14 

12 

10 

1)

Press and hold down the bottom key, until the message 

In

 is displayed. 

2)

Press the bottom key :  the current setting flashes. 

3)

Select an inversion frequency using the top key. 

4)

Confirm with the bottom key :  the display freezes for a moment. 

 

 

 

1 :

 

Red LED

    

2 :

 

Green LED 

3 :

 

Screen

 

4 :

 

Control keys

 

 

Non-binding image 

Summary of Contents for ELLY20NPSB-G0HX16

Page 1: ...PAPI004175 INTER3 Version 20 12 Instructions for use Instrucciones de uso Electrolyseur de sel Salt chlorinator Electrolizador de sal FRANCAIS ESPA OL ENGLISH...

Page 2: ...face 4 2 2 Mise en marche 4 2 3 4 2 4 en option 4 2 5 R glage de la consigne de production 5 2 6 Mode Boost en option 5 2 7 Prise Cover ou Ext en option 5 2 7 1 Configuration pr alable 5 2 7 2 5 2 8 A...

Page 3: ...fret lectronique H 8 I ci ELEMENTS NON FOURNIS 5 Alimentation lectrique 6 C ble de cuivre 7 Filtre 8 Piquet de terre 9 Pompe chaleur 10 Pompe de filtration KIT POOL TERRE en option 3 Electrode 4 Suppo...

Page 4: ...00 avec la touche du haut pas de validation requise au bout de quelques Le ventilateur interne au coffret lectronique peut ventuellement continuer tourner tant que le coffret est sous tension 2 4 R gl...

Page 5: ...mande externe ou un contact de position volet 2 7 1 Configuration pr alable I 1 In 2 CG 3 Appuyer sur la touche du bas un des affichages ci dessous clignote 4 Avec la touche du haut se positionner en...

Page 6: ...ques aux bornes de la cellule sont suffisamment serr es et non oxyd es bien raccord au coffret lectronique En dernier recours remplacer la cellule Probl me au niveau du coffret lectronique lectronique...

Page 7: ...nitiale Dans le but caract ristiques de ses fabrications ctuelle vis vis des tiers La garantie du constructeur qui couvre les d fauts de fabrication ne doit pas tre confondue avec les op rations d cri...

Page 8: ...the inversion frequency of the current supplying the cell optional 4 2 5 Setting the production setpoint 5 2 6 Boost mode optional 5 2 7 Cover or Ext socket optional 5 2 7 1 Pre configuration 5 2 7 2...

Page 9: ...ections at cell level must not point upwards to avoid any deposits of water or humidity on them ELEMENTS NOT SUPPLIED 5 Electrical power supply 6 Copper cable 7 Filter 8 Ground rod 9 Heat pump 10 Filt...

Page 10: ...ff and the red LED comes on The internal ventilator of the electronics unit can may be able to continue running as long as the unit is powered on 2 4 Adjustmentof theinversion frequencyofthecurrentsup...

Page 11: ...he top key x times until the message CG is displayed 3 Press the bottom key one of the following displays will flash 4 Using the top key move to position CF for connection to a flow sensor CE for conn...

Page 12: ...ted to the electronics unit Check that the cell is not scaled As a last resort replace the cell Problem in the electronics unit Contact a professional to repair the electronics unit A2 Short circuitin...

Page 13: ...e extend the original guarantee period Guarantee application limit In order to improve the quality of their products the manufacturer reserves the right to modify the characteristics of the products a...

Page 14: ...cuencia de inversi n de la corriente que alimenta la c lula opcional 4 2 5 Ajuste del punto de consigna de producci n 5 2 6 Modo Boost opcional 5 2 7 Toma Cover o Ext opcional 5 2 7 1 Configuraci n pr...

Page 15: ...a de la c lula no deben quedar orientadas hacia arriba para evitar que se acumule agua o humedad en ellas ELEMENTOS NO INCLUIDOS 5 Alimentaci n el ctrica 6 Cable de cobre 7 Filtro 8 Pica de tierra 9 B...

Page 16: ...validaci n al cabo de unos segundos la pantalla se apaga y el piloto rojo se ilumina El ventilador interno del cuadro el ctrico podr a seguir funcionando mientras el cuadro est conectado 2 4 Ajustedel...

Page 17: ...G 3 Pulsar en la tecla de abajo y aparecer parpadeando una de las siguientes visualizaciones 4 Con la tecla de arriba posicionarse en CF si conexi n a un captador de flujo CE si conexi n a un comando...

Page 18: ...e la c lula est exenta de cal Como ltimo recurso cambie la c lula Problema en el cuadro el ctrico Dirigirse a un profesional para que repare el cuadro el ctrico A2 Cortocircuito en el equipo Problema...

Page 19: ...t a inicial L mite de aplicaci n de la garant a Con el objetivo de mejorar la calidad de sus productos el fabricante se reserva el derecho de modificar en cualquier momento y sin previo aviso las cara...

Page 20: ......

Reviews: