AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082
–
FR/EN/ES/DE - Rev.03.16
18
1/ Standard functioning : %
✓
Chlorine production of the device settles in production percentage, from 0 to 100%, with those keys
.
✓
Adjust the production % in the way to maintain free chlorine rate in the pool between 0,5 and 1 ppm. In
the starting up, in first estimation, adjust with the following values :
Model 35
m
3
Model 55
m
3
Model 95
m
3
Model 160
m
3
Pool volume
(
m
3
)
% setting
Pool volume
(
m
3
)
% setting
Pool volume
(
m
3
)
% setting
Pool volume
(
m
3
)
% setting
35
m
3
100
55
m
3
100
95
m
3
100
160
m
3
100
30
m
3
90
50
m
3
90
85
m
3
90
140
m
3
90
25
m
3
80
45
m
3
80
75
m
3
80
120
m
3
80
20
m
3
70
40
m
3
70
65
m
3
70
100
m
3
70
15
m
3
60
35
m
3
60
55
m
3
60
90
m
3
60
Note : Every use of pool is different, it could be necessary several tests to determine the most adapted value to the situation.
2/ Pool equipped with a pool cover : LOW
✓
If your pool is equipped with a pool cover, the chlorine production must be reduced when the shutter is
shut (see 3.7).
✓
The device is equipped with a function that will take care of it automatically.
✓
Activate the « LOW » mode so that the production is automatically reduced when the shutter will be
shut :
✓
When the shutter will be shut, the device will display :
Function which can be used for a cover with
bubble (connecting in a switch) or for an internal pool
(permanent reduction of the production)
3/ Free chlorine regulation option (Poolsquad ® Ampéro) : CL
The Poolsquad Ampéro® has a free chlorination regulation thanks to an amperometric probe.
✓
The mode is called « Cl » and is already activated upon receipt of the
device.
✓
When installing the device :
➢
Check that the level of stabilizer (Cyanuric acid) is under 1 ppm :
Stabilizer has an impact on the reading of the chlorine probe and then corrupts the good functioning
of the regulation. If necessary, renew a part of the pool water.
➢
Add the gel in the probe:
1/ Switch off the device and unplug the probe. Close gates of the by-pass and bring out the probe of the
chamber of measure.
2/ Unscrew at half tank of the probe.
3/ Open the bottle of gel and expel the air. Pour the gel without making of air bubbles in the tank.
4/ Re-screw the tank and tight hardly. The gel surplus evacuated by the elastic ring.
➢
Calibrate the chlorine probe.
Measure the free chlorine rate of the pool with DPD reactive n°1 and record the value (it must be
between 0,8 and 2,5 ppm) :
CHLORINATION SALT
◄►
OK
MODE
% / LOW / Cl / OFF
◄►
OK
▼▲
CHLORINATION SALT
◄►
OK
MODE
% / LOW / Cl / OFF
◄►
OK
▼▲