2.8.2.
Important precautions regarding the peristaltic pump
This chapter is applicable if the electronics unit is fitted with a cover hiding the peristaltic pump.
I
When one of the messages below is displayed, the peristaltic pump is running. IN THIS CASE, DO NOT
REMOVE THE COVER OF THE ELECTRONICS UNIT COVERING THE PERISTALTIC PUMP.
Real-time timer countdown
or
To dismiss this display, press
OK
: the default display reappears, with the peristaltic pump on
indicator (small dot).
If case of doubt about the correct functioning of the peristaltic pump:
1)
Switch off the electronics unit.
2)
Remove the cover of the electronics unit which covers the peristaltic pump.
3)
Remove the internal pipe from the peristaltic pump, without removing the semi-rigid pipes connected to it.
4)
Check the condition of the peristaltic pump and internal pipes.
5)
Turn on the electronics unit.
6)
Carry out a manual vacuum injection.
7)
Check that the peristaltic pump is running correctly.
2.9.
Data history
Menu
Sub-menu
Content
-
Date of the last pH probe calibration
Duration of filtration pump operation the previous day
Average daily operating time of the filtration pump the previous week
Average daily operating time of the filtration pump the preceding month
Duration of peristaltic pump operation the previous day
Average daily operating time of the peristaltic pump the previous week
Average daily operating time of the peristaltic pump the preceding month
Cumulative duration of peristaltic pump operation since the first start-up of the
electronics unit
Average water temperature the previous day
Average water temperature for the previous week
Average water temperature for the previous month
2.10.
Additional information
Menu
Meaning
Control board program
Configuration code
Serial number
Bluetooth module MAC address
Internal temperature