Maintenance and cleaning
The unit has to be taken out of the water for cleaning or maintenance.
Cleaning the device
Recommendation regarding cleaning:
•
Clean the unit as required but at least twice a year.
•
When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
•
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
•
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
•
Clean the outside of the pump.
– Use a soft brush as an aid.
•
After cleaning, thoroughly rinse all parts in clean water.
How to proceed:
1. Disassemble the unit.
2. Clean the filter housing and impeller unit.
(→ Replacing the impeller unit)
3. Pull the nozzle unit apart.
4. Clean all parts.
– Use a soft brush as an aid.
– Rinse parts in clean water.
5. Clean the solar module with a damp cloth and wipe dry.
6. Reassemble the unit in the reverse order.
Replacing the impeller unit
How to proceed:
5
C
1. Pull the filter housing from the pump.
2. Remove the foam filter from the filter housing and rinse it out.
3. Pull the cover off the impeller unit (push-fit fastening, lever out carefully).
4. Pull out the impeller unit and clean or replace.
5. Reassemble the unit in the reverse order.
Wear parts
•
Foam filter
•
Impeller unit
Storage/overwintering
Observe the permissible operating temperature range. (
→
Technical data)
•
If the limit values are exceeded or gone below, it is necessary to remove the unit. Clean the unit thoroughly and check
it for damage.
•
Store the pump submerged and in a frost-free environment.