8
Contents
Safety precautions...................................................... 8
1. General information................................................ 8
2. Handling.................................................................8
3. Installation .............................................................9
3.1. Discharge pipe assembly................................. 9
3.2. Electrical connection........................................9
3.3. Pre-start checks...............................................9
4. Starting.................................................................. 9
5. Maintenance.........................................................10
6. Nameplate............................................................ 10
7. Possible faults, causes and solutions.....................10
8. Technical data....................................................... 11
9. List of main components........................................15
10. Wiring diagrams ................................................. 17
11. Illustrations ....................................................... 16
Safety precautions
This symbol
indicates the risk level
deriving from failure to observe the prescribed safety
precautions:
Warns that failure to observe the pre
cautions involves a risk of electric
shock.
Warns that failure to observe the pre
cautions involves a risk of damage to
persons and/or things.
Warns that failure to observe the pre
cautions involves the risk of damaging
the pump and/or the facility
DANGER
Risk of
electric
DANGER
WARNING
1. GENERAL INFORMATION
Please observe the following instructions to achieve the
best pump performance possible and a trouble free
installation.
Read these instructions before installing the
pump.
Save them for future reference.
The IDRA N / ARIANA N range consists of vertical
submersible pumps, easy to install and designed to
operate with clean water, free from elements in
suspension, at a maximum temperature of 35°C.
The IDRAMATIC models are pumps with built-in
electronic pressure regulator made up of a check valve
and control electronics. These pumps have been
designed to automate the starting and stopping process
and to prevent them from operating without water. With
water consumption of more than 1.4 l/minute (4.31 US
g.p.m.) the pump is always operational.
The IDRAMATIC models have a start-up pressure of 2
bar(1000)/3 bar(1200). The pump remains operational
while a faucet is Ieft running. The pump stops when, all
the faucets are closed.
Correct pump operation is assured providing
the instructions on electrical connection,
installation and use are strictly adhered to.
Failure to adhere to the instructions can result
in premature failure of the pump and voiding
of the warranty.
2. HANDLING
The pumps are supplied suitably packaged to prevent
damage in transit. Before unpacking, check that the
packaging has not been damaged or deformed.
Lift and handle the product with care and with
the right tools.
A
Warning! Observe limitations of use.
B
The name plate voltage must be the same as the mains voltage.
C
Connect the pump to the mains via an omnipolar switch with at
least a 3 mm opening between contacts.
D
Install a high-sensitivity differential switch (0.03A) as extra
protection against lethal electric shocks.
E
Connect the pump to the ground.
F
Use pump only within performance limits indicated on the name
plate.
G
Be careful with hazardous liquids and environments.
H
Do not carry the pump by the power cable.
I
This apparatus may be used by children older than 8 and persons
with reduced physical, sensory or mental capacities, or lacking
experience and knowledge, if they are supervised or receive
adequate training on the safe use of the apparatus and understand
the dangers.
Children should not be allowed to play with the apparatus.
Children should not perform the ordinary cleaning and maintenance
tasks without supervision.
J
The pump should only be dismantled by authorized personnel.
K
Cut the power supply before servicing the electrical pump.
L
Warning! Avoid icing.
Damage prevention and safety instructions
(see figure 9)
INSTRUCTION MANUAL (TRANSLATION FROM THE ORIGINAL SPANISH)
EN
Summary of Contents for ARIANA N
Page 2: ......
Page 16: ...16 Fig 1 Fig 2 Fig 3 ...
Page 17: ......
Page 18: ...18 A E I B F J C G K D H L Fig 9 ...
Page 20: ...cod 171038 04 2015 06 ...