10
Problem Causes
Solutions
1
No electricity
Check fuses and other protection devices
2
Drop in the well water level
Check that the pump is completely submerged
4
Voltage error
Check that the voltage is the same as indicated on the
name plate
3
Total manometric head greater than foreseen
Check geometric height plus head loss
1
Thermal protection activated
Reset the thermal protection or wait for it to cool
2
Discharge line disconnected
Connect this line to the outlet of the pump
3
Insufficient well flow
Install the gate valve on the outlet to reduce the flow of
the pump
3
Water intake filter clogged
Clean intake filter
1
Stop caused by level probes
Wait for the well to recover
2
Check valve installed in the wrong direction
Install the valve in the opposite direction
3
Wear in the hydraulics
Contact an Official Repair Center
1, 3 Capacitor not properly connected (version II)
See wiring diagram
3
Faulty discharge line
Replace the line with a new one
1
Power cable cut
Check the power cable
5. MAINTENANCE
These submersible pumps do not require maintenance.
During frosty periods, remember to drain the
line.
If the pump will be out of service for extended
periods, it should be removed from the well
and stored in a dry, well-ventilated location.
Warning: If the power cable is damaged, it must be
replaced by the manufacturer, its after-sale service or
similarly qualified persons to avoid a hazard.
The
Official
Technical
Services
list
is
in
www.pompesguinard-loisirs.fr
When the pump is eventually disposed of, please note
that it contains no toxic or polluting material. All main
components are material identified to allow selective
disposal
7. TECHNICAL DATA
Liquid temperature: ..................................... 4ºC - 35ºC
Ambient temperature: ....................................0ºC -40ºC
Storage temperature: .................................-10ºC - 50ºC
Ambient relative humidity, max.: 95%
Motor class I.
Other data see Figure 10.
8. TROUBLESHOOTING
1. The pump does not start.
2. The pump works but does not produce any flow.
3. The flow does not match the supplied curve.
4. The pump stops automatically.
6. PLATE SHOWING CHARACTERISTICS
1 Item reference
2 V fre item specifications
3 Flow
4 Pressure
5 Nominal voltage, no. stages, alternate current symbol and
frequency
6 Capacitor (Single-phase model)
7 EC mark + year of manufacture
8 Humidity protection level
9 Motor max. nominal output (P2)
10 Minimum working pressure
11 Maximum pressure
12 Pump serial no. (Fig.8)
13 Max. liquid temperature
14 Max. immersed depth
15 Electric pump unit absorbed power(P1)
16 Designated motor insulation
17 Continuous operation symbol
18 Maximum nominal intensity at nominal voltage
19 Name and address of vendor responsible for the product
EN
Summary of Contents for ARIANA N
Page 2: ......
Page 16: ...16 Fig 1 Fig 2 Fig 3 ...
Page 17: ......
Page 18: ...18 A E I B F J C G K D H L Fig 9 ...
Page 20: ...cod 171038 04 2015 06 ...